Jendrassik--Grof analysis for total and direct bilirubin in serum with a centrifugal analyzer.

نویسنده

  • C C Garber
چکیده

Total bilirubin is determined here with a multipoint calibration approach and with use of Standard Reference Material No. 916 bilirubin from the National Bureau of Standards. The bilirubin calibration solutions prepared in solutions of Cohn Fraction V human albumin were stable for at least one year when stored at -80 degrees C. Studies for direct bilirubin analysis show that the serum sample should be preincubated with the HCI reagent before the diazo reagent is added to minimize the false reaction with unconjugated bilirubin. With a preincubation of 15 min and a reaction interval of 15 min a 250 mg/L unconjugated bilirubin standard gave only 1 mg of apparent conjugated bilirubin per liter. Day-to-day precision studies gave CVs of 3.3% at 12.4 mg/l, 2.1% at 41.2 mg/l, and 1.0% at 197.4 mg/L for total bilirubin and 1.6% at 61.2 mg/L for direct bilirubin, the latter based on a serum pool stored at -80 degrees C. Lipemic sera caused negligible errors. Hemolysis caused slightly larger errors for total bilirubin but much smaller errors for direct bilirubin when measured at 600 nm rather than 550 nm. Comparison of results with the Rotochem (y) to those with a manual Jendrassik--Grof method (x) for total bilirubin gave y = 0.9009x - 0.04 mg/L, Sy/x = 1.3 mg/L, r = 0.9987 when different calibrators were used for each method and y = 0.9813x - 2.9 mg/L, Sy/x = 1.5 mg/L, r = 0.9997 when the same calibrators were used. For direct-bilirubin comparisons, y = 1.2762x + 0.2 mg/L, Sy/x = 1.3 mg/L, r = 0.9926.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated Jendrassik-Grof method for measurement of bilirubin in serum with the Greiner Selective Analyzer (GSA II D), and comparison with the method involving diazotized 2,4-dichloroaniline.

We automated the Jendrassik-Grof method for measurement of bilirubin with the Greiner Selective Analyzer GSA II D. Comparison with the manual Jendrassik-Grof method showed a highly significant correlation coefficient of 0.994 for total and 0.980 for "direct" bilirubin measurement. The automated method showed good precision and was linear to 667 mu mol/L, the highest concentration tested. Additi...

متن کامل

Centrifugal analyzer method for total bilirubin in serum by use of diazotized 2-chloroaniline-5-sulfonic acid.

We describe two centrifugal analyzer methods for measuring total bilirubin in serum. Diazotized 2-chloroaniline-5-sulfonic acid is used in both. In the first procedure, ethylene glycol and methanol are used as an accelerator solvent; results correlate well with those by a Jendrassik and Grof method adapted to the centrifugal analyzer, but there is considerable hemolysis interference. In the sec...

متن کامل

Adaptation of blank-corrected methods for measurement of total and conjugated bilirubin and uric acid to the centrifugal analyzer.

The blank-corrected determination in serum of total and conjugated bilirubin and of uric acid has been adapted to the centrifugal analyzer. Bilirubin is measured by a modified Jendrassik and Grof procedure; uric acid is determined kinetically by using a reaction based on reduction of ferric ion, including a uricase-treated blank. Sensitivity and precision of both methods are excellent, and resu...

متن کامل

Modified Jendrassik--Grof method for bilirubins adapted to the Abbott Bichromatic Analyzer.

I describe a semi-micro method for use with a discrete analyzer, the Abbott ABA-100, requiring 75 microliter of sample for determination of both the total and direct bilirubins. This method utilizes a serum blank. It is simple and reasonably rapid. The azobilirubin formed by both the total and the direct bilirubins produces a reddish-violet color, which is measured at 550 nm. Values obtained ar...

متن کامل

New kinetic procedure for the measurement of conjugated bilirubin with a centrifugal analyzer.

A procedure has been developed for the automated measurement of conjugated bilirubin in serum with a centrifugal analyzer. The conjugated bilirubin is measured by a fixed time kinetic method which monitors the reaction between conjugated bilirubin and diazotized sulfanilic acid at 550 nm. Results are calculated based on a comparison of the reagent blank-corrected absorbance changes between 15 s...

متن کامل