Strategies for shimming the breast.

نویسندگان

  • Nimrod Maril
  • Christopher M Collins
  • Robert L Greenman
  • Robert E Lenkinski
چکیده

There is evidence in the literature indicating a significant static field inhomogeneity in the human breast. A nonhomogenous field results in line broadening and frequency shifts in MRS and can cause intensity loss and spatial errors in MRI. Thus, there is a clear rationale for determining the regional variations in the static field homogeneity in the breast and providing strategies to correct them. Herein, the nature and extent of the static magnetic field at 3 T were measured in central planes of the human breast using both phase maps and multivoxel MRS techniques. In addition, the effect of first- and high-order shimming and of spatial saturation pulses on the static field inhomogeneity was evaluated. Both the theoretical and the measured field were found to be primarily linear in nature, with a reduction of 300 Hz from the nipple to the chest wall. First-order shimming reduced this inhomogeneity by 65%. Interestingly, the combination of spatial saturation pulses and first-order shimming was more effective than high-order shim alone. Since many clinical scanners do not have either higher-order shim or automated higher shimming algorithms that work in the presence of fat, the suggested combination provides an effective means to correct inhomogeneities in the breast.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A robust automated shimming procedure for breast MR spectroscopy

Introduction Proton magnetic resonance spectroscopy (H-MRS) offers attractive possibilities for the non-invasive in vivo assessment of breast lesion biochemistry, as an aid for diagnosis [1] and an early indicator of disease response to treatment [2-4]. Effective shimming to achieve a high magnetic field homogeniety over the volume of interest (VOI) is paramount for MRS to achieve sufficient sp...

متن کامل

Anatomy-specific B0-Shimming Strategies for Robust Clinical Imaging

Inadequate B0-shimming regularly results in suboptimal clinical image quality for several imaging and spectroscopic techniques. Linear shimming is generally a standard commercial offering, and higher-order shimming hardware is also available; however, these tools can be highly operator-dependent. While sporadic recommendations are in the literature, in practice, shimming strategies are typicall...

متن کامل

MRS Shimming: An Important Point Which Should not be Ignored

Introduction: Proton magnetic resonance spectroscopy (MRS) is a well-known device for analyzing the biological fluids metabolically. Obtaining accurate and reliable information via MRS needs a homogeneous magnetic field in order to provide well-defined peaks and uniform water suppression. There are lots of reasons which can disturb the magnetic field homogeneity which can be corrected by a proc...

متن کامل

Improved B1 Homogeneity and Reduced Transmit Power with 4-channel Regional RF Shimming for Breast Imaging at 3 T

Target audience: Researchers and engineers who have interest in RF transmit technology in high field MRI. Purpose: The B1 inhomogeneity is one of the problems for breast imaging at 3 T. Various methods using multiple channel RF transmit coil or using some additional dielectric absorptive material are investigated to overcome this problem [1, 2]. These studies showed the number of channels of RF...

متن کامل

The Mediating Role of Cognitive Emotion Regulation Strategies Between Anxiety and Body Image in Women With Breast Cancer Volunteer For Mastectomy

Background: Breast loss is a major concern for breast cancer patients because they feel that their femininity symbol has been damaged. In the present study, we investigate the mediating role of cognitive emotion regulation in the relationship between anxiety and body image in women with breast cancer volunteer for mastectomy. Methods: The research method is correlational, the study population...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 54 5  شماره 

صفحات  -

تاریخ انتشار 2005