Catheterization and Cardiovascular Diagnosis 10507-513 (1984) Thresholds for Transesophageal Atrial Pacing
نویسندگان
چکیده
To determine the thresholds for transesophageal atrial capture, as well as factors that may influence the thresholds, we measured the minimal current and pulse width required to pace the atria through transesophageal bipolar lead systems in 12 patients, ranging in age from l day to 19 years, during 19 episodes of reentrant supraventricular tachycardia. Depending on the patients’ age and size several electrode catheters were used. The protocol called for 1-msec step-wise increments in pulse width. At each pulse width the current was increased by 1 mamp until capture was achieved. The mean minimal pulse width and mean minimal current required for capture were 5.8 msec and 13.6 mamp, respectively. Atrial capture was achieved in 75% of attempts at a pulse width and current equal to or less than 6.5 msec and 17.5 mamp, respectively. No correlation between current and pulse width on the one hand and age, height, weight, or body surface area on the other was detected. Likewise neither electrode type nor existence of structural heart disease influenced the threshold required for capture. We conclude that atrial capture can be readily achieved through transesophageal electrodes and is not influenced by the subject’s age or size.
منابع مشابه
Stress echocardiography with transesophageal atrial pacing: preliminary report of a new method for detection of ischemic wall motion abnormalities.
We performed two-dimensional echocardiography in 19 patients with significant coronary artery disease and in six normal volunteers at rest and during transesophageal atrial pacing. Technically adequate resting echocardiograms were obtained in 18 of the 19 patients and in all six normal volunteers. In two subjects, atrial capture was not possible, and in one subject, discomfort from the pacing a...
متن کاملTransesophageal pacing : a versatile diagnostic and therapeutic tool
Transesophageal pacing and recording is done using specialized or non specialized catheters. There are two different lead types: 1) the pill electrode, connected to a flexible wire, that the patient swallows with water. This pill electrode necessitates patient collaboration. 2) a flexible catheter that can even be used in comatose or intubated patients. The pacing lead, in our cases a bipolar f...
متن کاملThe Improvement of the Atrial Flutter Rhythm upon the Removal of the Infected Permanent Pacemaker Lead
Pacemaker infection has multiple risk factors. Its presentation is most often similar to infected endocarditis and the diagnosis is made through studying blood cultures. Transesophageal echocardiography can confirm the diagnosis. The most common microorganisms are staphylococcus speciesis. As a matter of fact, complete pacemaker removal appears to be the only definite treatment. We presented a ...
متن کاملInteratrial Block: A Virtual Pandemic Requiring Attention
Interatrial block (IAB) denotes a conduction delay between the two atria (P-wave duration ≥110 ms). Depending on the severity of the block, IAB can be partial or advanced. Even though several studies have reported a high prevalence of IAB, it still remains a diagnosis many neglect without any follow-up. The crisis in IAB is undramatic until predictable complications appear. Nevertheless, the da...
متن کاملEvaluation of transesophageal atrial pacing in the prone and lateral positions.
OBJECTIVE To develop recommendations for positioning the second-generation pacing esophageal stethoscope for transesophageal atrial pacing in patients positioned prone (P), right lateral decubitus (RLD), and left lateral decubitus (LLD). DESIGN Prospective; patients assigned consecutively. SETTING Tertiary and university hospitals. PARTICIPANTS Thirty (10 in each position group) adult pat...