Practical use of the raw electroencephalogram waveform during general anesthesia: the art and science.

نویسندگان

  • Cambell Bennett
  • Logan J Voss
  • John P M Barnard
  • James W Sleigh
چکیده

Quantitative electroencephalogram (qEEG) monitors are often used to estimate depth of anesthesia and intraoperative recall during general anesthesia. As with any monitor, the processed numerical output is often misleading and has to be interpreted within a clinical context. For the safe clinical use of these monitors, a clear mental picture of the expected raw electroencephalogram (EEG) patterns, as well as a knowledge of the common EEG artifacts, is absolutely necessary. This has provided the motivation to write this tutorial. We describe, and give examples of, the typical EEG features of adequate general anesthesia, effects of noxious stimulation, and adjunctive drugs. Artifacts are commonly encountered and may be classified as arising from outside the head, from the head but outside the brain (commonly frontal electromyogram), or from within the brain (atypical or pathologic). We include real examples of clinical problem-solving processes. In particular, it is important to realize that an artifactually high qEEG index is relatively common and may result in dangerous anesthetic drug overdose. The anesthesiologist must be certain that the qEEG number is consistent with the apparent state of the patient, the doses of various anesthetic drugs, and the degree of surgical stimulation, and that the qEEG number is consistent with the appearance of the raw EEG signal. Any discrepancy must be a stimulus for the immediate critical examination of the patient's state using all the available information rather than reactive therapy to "treat" a number.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

استخراج دینامیک سیگنال مغزی در حالت های مختلف بیهوشی به کمک تحلیل طرح پوآنکاره

 Aims and background: Poincare plot and its length and width are known as a criterion for short-term variations of electroencephalogram signals )EEGs(. This study evaluates the effect of time delay on changes in the width of the Poincare plot in brain signal during different anesthesia states. Materials and Methods: Poincare plots are drawn with one to six delay in three sets, including awake s...

متن کامل

Evaluation of Mexiletine Effect on Bispectral Index Changes and Hemodynamic Responses to Endotracheal Intubation and During General Anesthesia

  Background &Objective: Plaryngoscopy and tracheal intubation increase not only blood pressure and heart rate but also Bispectral Index (BIS) of the patients. In this study, hemodynamic and BIS changes were surveyed after tracheal intubation and during general anesthesia followed by mexiletine prescription . Materials & Methods: In this study, 50 patients aged between 20 and 60 who were ca...

متن کامل

Perioperative care of the elderly patient with hip fracture.

1. Akeju O, Pavone KJ, Westover MB, Vazquez R, Prerau MJ, Harrell PG, Hartnack KE, Rhee J, Sampson AL, Habeeb K, Gao L, Lei G, Pierce ET, Walsh JL, Brown EN, Purdon PL: A comparison of propofoland dexmedetomidine-induced electroencephalogram dynamics using spectral and coherence analysis. ANESTHESiOLOGy 2014; 121:978–89 2. Purdon PL, Pierce ET, Mukamel EA, Prerau MJ, Walsh JL, Wong KF, Salazar-...

متن کامل

A practical and convenient method for the synthesis of anesthetic drug thiopental: using thiourea and sodium ethoxide

A general, simple, practical and convenient method has been described for the synthesis of anesthetic drug thiopental using thiourea in the presence of sodium ethoxide. Anesthetic drug of thiopental was prepared in two stages; during the first stage, the alkylation of mthyl cyanoacetate was performed which was then to be followed by cyclization. Alkylation of methyl cyanoacetate which was perfo...

متن کامل

بررسی ثبت مداوم الکتروآنسفالوگرام در کنترل عمق بیهوشی بیماران سالمند

Background and Objective: The Bispectral Index (BIS) is a neurophysiologic monitoring system, which continuously analyzes the electroencephalogram recording of a patient during general anesthesia to assess the patient's level of consciousness. When one is awake, the brain cortex is very active, with marked EEG signals. However, during sleep or under general anesthesia, the signal patterns chang...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 109 2  شماره 

صفحات  -

تاریخ انتشار 2009