Charge-coupled device area x-ray detectors

نویسندگان

  • Sol M. Gruner
  • Mark W. Tate
  • Eric F. Eikenberry
چکیده

Charge-coupled device ~CCD! area x-ray detector technology is reviewed. CCD detectors consist of a serial chain of signal components, such as phosphors, fiber optics or lenses, image intensifiers and the CCD which serve to convert the x-ray energy to light or electron-hole pairs and to record the spatially resolved image. The various combinations of components that have been used to make CCD detectors are described and the properties of each of the critical components are discussed. Calibration and correction procedures required for accurate data collection are described. The review closes with a brief description of future directions for solid-state area x-ray detectors. © 2002 American Institute of Physics. @DOI: 10.1063/1.1488674#

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration procedures for charge-coupled device x-ray detectors

Calibration procedures are described for use with electronic x-ray detectors, with an emphasis on detectors based on fiber-optically coupled charge-coupled devices. Methods are detailed for removing spurious events, pixel pedestals, dark-current, spatial distortion, and intensity response variations for both small-angle and wide-angle applications. The accuracy of the calibration procedures is ...

متن کامل

Research Highlights1

Recently introduced electronic area X-ray detectors (such as CCD based detectors) are having an enormous impact within the experimental x-ray community. The efficiency and ease of data collection has been improved considerably. They are also making practical the implementation of powerful new methodologies in data collection such as fine rotation slicing of crystallography data or multi-wavelen...

متن کامل

X-ray emission during the muonic cascade in hydrogen

We report our investigations of X rays emitted during the muonic cascade in hydrogen employing charge coupled devices as X-ray detectors. The density dependence of the relative X-ray yields for the muonic hydrogen lines ( Kα, Kβ and Kγ) has been measured at densities between 0.00115 and 0.97 of liquid hydrogen density. In this density region collisional processes dominate the cascade down to lo...

متن کامل

MeV X-ray imaging using plastic scintillating fiber area detectors: a simulation study.

Due to their low cost, flexibility, and convenience for long distance data transfer, plastic scintillating fibers (PSFs) have been increasingly used in building detectors or sensors for detecting various radiations and imaging. In this work, the possibility of using PSF coupled with charge-coupled devices (CCD) to build area detectors for X-ray imaging is studied using a Monte Carlo simulation....

متن کامل

Synchrotron Area X-ray Detectors, Present and Future

X-ray experiments are very frequently detector limited at today’s storage ring synchrotron radiation (SR) sources, and will be even more so at future Energy Recovery Linac and X-ray Free Electron Laser sources. Image plate and phosphor-coupled CCD detectors that predominate at present-day sources were outgrowths of technologies initially developed for the medical and astronomical communities, r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002