A comparison between size of the occluder device and two-dimensional transoesophageal echocardiographic sizing of the ostium secundum atrial septal defect

نویسندگان

  • Alimohammad Hajizeinali
  • Mohammad Alidoosti
  • Hakimeh Sadeghian
  • Arezoo Zoroufian
  • Mehrnaz Rezvanfard
  • Marat A Volman
چکیده

OBJECTIVES Transcatheter closure of a secundum atrial septal defect (ASD II) has become an effective alternative for surgical treatment. In this study we evaluated the correlation between the two-dimensional transoesophageal echocardiographic (2D TEE) sizing of ASDs and the actual diameter of occluders in patients undergoing device closure. METHODS The records of 54 patients who underwent transcatheter ASD closure were reviewed. ASD characteristics and maximum defect diameter were evaluated using preprocedure 2D TEE images. Appropriate device size was determined by the balloon sizing method, which measures the balloon occlusive diameter (BOD) via TEE and fluoroscopy. ASD closure was performed under continuous TEE monitoring using the Amplatzer occluder in all patients. RESULTS The mean of the TEE-derived maximum defect diameter was significantly lower than the mean of the BOD (17.8 ± 4.5 vs 22.1 ± 5.1 mm; p < 0.001) and the mean size of the implanted occluder device (17.8 ± 4.5 vs 23.3 ± 5.1 mm; p < 0.001). However, a good correlation was found between the TEE-derived defect size and the BOD (BOD = 0.898 × TEE defect size + 6.212, R = 0.824; p < 0.001) and between the TEE measurement and the final size of the implanted Amplatzer (device size = 0.928 × TEE defect size + 6.853, R = 0.822; p < 0.001). CONCLUSION 2D TEE may provide a good equation to predict the BOD or the size of the occluder device; however, further studies are needed to investigate whether it is feasible to perform transcatheter ASD occlusion without balloon sizing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Live/Real Time Three-Dimensional Trans Esophageal Echocardiographic Findings in Amplatzer ASD Closure Devices in Adults

Six female patients aged from 19 to 73 years, with ostium secundum atrial septal defect underwent closure procedure with Amplatzer septal occluder device. Three-dimensional Echocardiography (3D-TEE) was done during the procedure or one day after the procedure. 3D-TEE provides incremental value over Two- dimensional trans-esophageal echocardiography in measuring Amplatzer septal occluder disc si...

متن کامل

Transcatheter closure of atrial septal defects with transthoracic echocardiography.

OBJECTIVES The aim of this study is to evaluate our clinical experience using an Amplatzer septal occluder for catheter closure of a secundum atrial septal defect under transthoracic echocardiography guidance without general anaesthesia. METHODS Patients eligible for transcatheter atrial septal defect closure were selected using transthoracic echocardiography. The largest defect diameter meas...

متن کامل

Percutaneous retrieval of an interatrial septal occluder device embolized into the aortic arch.

Percutaneous closure of secundum atrial septal defects (ASD) may be complicated by immediate embolization. We report on a 35-year-old woman who underwent percutaneous device closure for a secundum ASD. The diameter of the defect was measured as 4 mm by two-dimensional transesophageal echocardiography and a 7-mm Figulla ASD occluder device was implanted without prior balloon sizing of the defect...

متن کامل

Detection of ostium secundum atrial septal defects by transoesophageal cross-sectional echocardiography.

Transoesophageal cross-sectional echocardiography has special advantages when investigating the interatrial septum which is imaged perpendicularly without echo dropouts from an oesophageal transducer position. The technique was successfully used in 19 out of 20 patients (95%) with an ostium secundum atrial septal defect and in 30 control subjects. In all of the latter the interatrial septum was...

متن کامل

[Correction of the perpendicular positioning of the Amplatzer device during closure of an ostium secundum atrial septal defect].

INTRODUCTION AND OBJECTIVES Ostium secundum atrial septal defects require closure. Echocardiographic studies have reported that, in 7% of cases, the Amplatzer occluder is orientated perpendicular to the rim of the defect. This article describes the use of an ancillary technique involving a balloon catheter that enables the Amplatzer device to be positioned transversely. METHODS We report six ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 24  شماره 

صفحات  -

تاریخ انتشار 2013