Utilizing of Square Wave Voltammetry to Detect Flavonoids in the Presence of Human Urine

نویسندگان

  • Vojtech Adam
  • Radka Mikelova
  • Jaromir Hubalek
  • Pavel Hanustiak
  • Miroslava Beklova
  • Petr Hodek
  • Ales Horna
  • Libuse Trnkova
  • Marie Stiborova
  • Ladislav Zeman
  • Rene Kizek
چکیده

About biological affecting of flavonoids on animal organisms is known less,thus we selected flavonoids, flavanones and flavones, and their glycosides, which wereexamined as potential inducers of cytochrome(s) P450 when administrated by gavages intoexperimental male rats. The study was focused on induction of CYP1A1, the majorcytochrome P450 involved in carcinogen activation. The data obtained demonstrate thenecessity of taking into account not only ability of flavonoids to bind to Ah receptor(induction factor) but also to concentrate on their distribution and metabolism (includingcolon microflora) in the body. After that we examined certain flavonoids as potential inducers of cytochrome P450, we wanted to suggest and optimize suitable electrochemical technique for determination of selected flavonoids (quercetin, quercitrin, rutin, chrysin and diosmin) in body liquids. For these purposes, we selected square wave voltannetry using carbon paste electrode. Primarily we aimed on investigation of their basic electrochemical behaviour. After that we have optimized frequency, step potential and supporting electrolyte. Based on the results obtained, we selected the most suitable conditions for determination of the flavonoids as follows: frequency 180 Hz, step potential 1.95 mV/s and phosphate buffer of pH 7 as supporting electrolyte. Detection limits (3 S/N) of the flavonoids were from units to tens of nM except diosmin, where the limit were higher than μM. In addition, we attempted to suggest a sensor for analysis of flavonoids in urine. It clearly follows from the results obtained that flavonoids can be analysed in the presence of animal urine, because urine did not influence much the signals of flavonoids (recoveries of the signals were about 90 %).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Nicotinic Acid by Square Wave Voltammetry on a Carbon Paste Electrode: the Crucial Effect of Electrode Composition and Analytical Conditions

The foregone studies have shown that nicotinic acid cannot produce noticeable reductive signal at carbon-based electrodes without appropriate modification of the electrode. This is an obvious reason that mercury is known as the main electrode material for electro-reduction of nicotinic acid. In this study, it has been shown that it is possible to create a remarkable reduction signal for NA at a...

متن کامل

Voltammmetric Determination of Captopril Using Multiwall Carbon Nanotubes Paste Electrode in the Presence of Isoproterenol as a Mediator

The electrocatalytic oxidation of captopril (CAP) was studied by modified carbon nanotubes paste electrode in the presence of isoproterenol (ISPT) using cyclic voltammetry (CV), chronoamperometry and square wave voltammetry (SWV). Also, the values of catalytic rate constant (k), and electron transfer coefficient (α) for CAP were calculated. The mechanism of CA electrochemical behavior at the mo...

متن کامل

Voltammmetric Determination of Captopril Using Multiwall Carbon Nanotubes Paste Electrode in the Presence of Isoproterenol as a Mediator

The electrocatalytic oxidation of captopril (CAP) was studied by modified carbon nanotubes paste electrode in the presence of isoproterenol (ISPT) using cyclic voltammetry (CV), chronoamperometry and square wave voltammetry (SWV). Also, the values of catalytic rate constant (k), and electron transfer coefficient (α) for CAP were calculated. The mechanism of CA electrochemical behavior at the mo...

متن کامل

Voltammetric determination of glutathione in pharmaceutical and biological samples using multiwall carbon nanotubes paste electrode in the presence of rutin as a mediator

A new sensitive, selective and nonexpensive electrochemical sensor was developed for electrocatalyticdetermination of glutathione (GSH)in pharmaceutical and biological samples. GSH is a tripeptide thiol present in all eukaryotic and probiotic cells. A voltammetric studyof GSH has been carried out at the surface of carbon paste electrode modified with multiwall carbon nanotubes(MWCNTPE) in the p...

متن کامل

Voltammetric determination of glutathione in pharmaceutical and biological samples using multiwall carbon nanotubes paste electrode in the presence of rutin as a mediator

A new sensitive, selective and nonexpensive electrochemical sensor was developed for electrocatalyticdetermination of glutathione (GSH)in pharmaceutical and biological samples. GSH is a tripeptide thiol present in all eukaryotic and probiotic cells. A voltammetric studyof GSH has been carried out at the surface of carbon paste electrode modified with multiwall carbon nanotubes(MWCNTPE) in the p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2007