Simultaneous in situ measurement of CO, H2O, and gas temperatures in a full-sized coal-fired power plant by near-infrared diode lasers.
نویسندگان
چکیده
We present what is to our knowledge the first near-infrared diode-laser-based absorption spectrometer that is suitable for simultaneous in situ measurement of carbon monoxide, water vapor, and temperature in the combustion chamber (20-m diameter, 13-m path length) of a 600-MW lignite-fired power plant. A fiber-coupled distributed-feedback diode-laser module at 1.56 microm served for CO detection, and a Fabry-Perot diode laser at 813 nm was used to determine H2O concentrations and temperature from multiline water spectra. Despite severe light losses (transmission, <10(-8)) and strong background radiation we achieved a resolution of 1.9 x 10(-4) (1sigma) fractional absorption, equivalent to 200 parts in 10(6) by volume of CO (at 1450 K, 10(5) Pa) with 30-s averaging time.
منابع مشابه
2002-02 LACEA Braunkohle end.PDF
A diode laser based in situ absorption spectrometer is presented for the simultaneous detection of CO (1560nm), water (813nm) and the gas temperature within the combustion chamber of a 600MW lignite-fired power-plant. A fractional absorption resolution better than 10 equivalent to a few hundred ppmV CO could be demonstrated with a 30 sec time response. ? 2000 Optical Society of America OCIS cod...
متن کاملImprovement of Efficiency of Coal-Fired Steam Power Plant by Reducing Heat Rejection Temperature at Condenser Using Kalina Cycle
This paper proposes an approach for improving the plant efficiency by reducing the heat rejection temperature of power cycle using Kalina Cycle System 11 (KCS11) which is integrated at the steam condenser of a 500 MWe SubC (subcritical) coal-fired power plant. It is modelled by using power plant simulation software ‘Cycle Tempo’ at different plant operating conditions. Results show t...
متن کاملHigh Temperature In-situ-detection of Atomic Potassium with Nir-diode Lasers
A laser-based in-situ spectrometer using near infrared diode laser at 767 and 770 nm to detect potassium atoms in high-temperature environments is described. The device was used to investigate the thermal dissociation of KCl and to monitor K behind the flue gas filter (300mm diameter, 1000°C) of a 250kW-coal combustor, without the necessity of error prone gas sampling. With a response time of 2...
متن کاملRadon monitoring in gas turbine and thermal power station A comparative study
Background: In this study, measurement of indoor radon and its progeny levels was carried out in Gas Turbine Power Station in Haryana ( India ), where natural gas is used as fuel. For comparison, the results of a study carried out in thermal power plant in Haryana are also presented. Radon being a ubiquitous air pollutant has global impact and its monitoring in the environment at work places is...
متن کاملRadioactivity level of soil around a coal-fired thermal power plant of northwest China
Background: The activity concentrations of natural radionuclides in soil around a coal-fired thermal power plant of northwest China were investigated for assessing the radioactivity level. Materials and Methods: Soil samples were collected around the coal-fired thermal power plant and their radioactivity levels were determined using gamma ray spectrometry. Radiation hazards were assessed by rad...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Applied optics
دوره 42 12 شماره
صفحات -
تاریخ انتشار 2003