The effect of implant size and device keel on vertebral compression properties in lumbar total disc replacement.

نویسندگان

  • Joshua D Auerbach
  • Carrie M Ballester
  • Frank Hammond
  • Ehren T Carine
  • Richard A Balderston
  • Dawn M Elliott
چکیده

BACKGROUND CONTEXT Vertebral end plate support is necessary for successful lumbar total disc replacement (TDR) surgery. Failure to achieve anterior column support as a result of lumbar TDR device undersizing could lead to implant subsidence and fracture. PURPOSE The purpose of the study was to examine the compressive biomechanical behavior of the vertebral end plate with varying sizes of disc replacement implants. STUDY DESIGN The study design comprises a biomechanical investigation using a human cadaveric lumbar spine model. METHODS Fifty-six vertebrae with intact posterior elements were prepared from 13 fresh frozen lumbar spines. Peripheral quantitative computed tomography was performed to assess regional bone density. Vertebrae were potted and subjected to nondestructive compression testing with a small, medium, and large custom-made implants with the footplate geometry of the ProDisc-L TDR (Synthes Spine, West Chester, PA, USA) system and having no keel. Failure testing was performed using the ProDisc-L implant with an intact keel. Pressure sensor film was used to assess contact pressure and distribution. RESULTS There was a linear correlation between percent coverage of the end plate and implant-end plate stiffness (p=.0001) and an inverse correlation with displacement (p=.01). The difference in implant-end plate stiffness between small-medium, medium-large, and small-large implants was 10.5% (p=.03), 10.2% (p=.02), and 19.6% (p<.0001), respectively. Failure analysis revealed similar trends for implant sizing, but only bone density was found to significantly correlate with failure properties (r=0.76, p<.0001). There was a significant reduction in implant-end plate stiffness of 18% when the keel was intact compared to without the keel (range 6-27%, p=.0008). Pressure film analysis revealed that the implant was loaded peripherally and did not have central contact during nondestructive loading. There was a trend toward greater contact pressure with the small implant when compared with the medium implant (p=.06) and the large implant (p=.06). CONCLUSIONS Although larger implants reduce end plate displacement, increase apparent implant-end plate stiffness, increase the implant-end plate contact area, and decrease the peak contact pressures, low bone density reduces failure properties. The keel introduces a reduction in stiffness to the implant-end plate interface, the clinical significance of which is currently unknown.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Parallax Effect in the Evaluation of Range of Motion in Lumbar Total Disc Replacement

BACKGROUND Range of motion (ROM) has been shown to influence clinical outcomes of total disc replacement (TDR). While the parallax effect in image acquisition has been shown in the literature to influence the accuracy of a variety of measurements, this concept has not been investigated in the assessment of ROM analysis following TDR. We performed an evaluation of the influence of radiograph bea...

متن کامل

Finite Element Study of a Lumbar Intervertebral Disc Nucleus Replacement Device

Nucleus replacement technologies are a minimally invasive alternative to spinal fusion and total disc replacement that have the potential to reduce pain and restore motion for patients with degenerative disc disease. Finite element modeling can be used to determine the biomechanics associated with nucleus replacement technologies. The current study focuses on a new nucleus replacement device de...

متن کامل

A novel modification for removal of the polyethylene core in artificial disc retrieval using a transpsoas minimally invasive technique.

Total disc replacement (TDR) surgeries have significantly increased in number since US FDA approval. However, the associated complications such as implant malposition, loosening, subsidence, implant migration, fractures, and infection may necessitate retrieval of the artificial disc and proceeding with interbody fusion. Retrieval of artificial discs in proximity to important vascular, urologica...

متن کامل

Does Vertebral Endplate Morphology Influence Outcomes in Lumbar Disc Arthroplasty? Part I: An Initial Assessment of a Novel Classification System of Lumbar Endplate Morphology

BACKGROUND The influence of lumbar endplate morphology on the clinical and radiographic outcomes of lumbar disc arthroplasty has not been evaluated to the best of our knowledge. STUDY DESIGN AND OBJECTIVE In this observational study of 80 patients, the objective was to formulate a reproducible and valid lumbar endplate classification system to be used in evaluating lumbar total disc replaceme...

متن کامل

Total disc replacement positioning affects facet contact forces and vertebral body strains.

STUDY DESIGN A validated nonlinear three-dimensional finite element (FE) model of a single lumbar motion segment (L3-L4) was used to evaluate the effects of total disc replacement (TDR). The model was implanted with a fixed-bearing TDR (ProDisc-L) at 2 surgically relevant positions and exercised about the 3 anatomic axes. Facet forces, range of motion (RoM), and vertebral body strains were eval...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The spine journal : official journal of the North American Spine Society

دوره 10 4  شماره 

صفحات  -

تاریخ انتشار 2010