This paper presents the microcontroller based advanced technique to design and development of a portable radiation survey meter to measure low level gamma radiation using NAI(T1) scintillation detector. A scintillation detector was used as radiation detector and a microcontroller PIC16F876 was used to control the function of the developed system. The microcontroller generated square wave frequency at specified pulse width to produce high voltage (+1200V) and regulates it. The high voltage was required to activate the scintillation detector. Preamplifier and amplifier were designed to make the detector signal for the further amplification. Microcontroller senses the pulses from the amplifier output and processes data by software and displays the results. The microcontroller was programmed using a high level programming language ‘C’ with PCWH compiler.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preliminary study on the properties of zinc oxide (ZnO) for alpha particles detection

Background: : Due to the difficulties of locally obtaining ZnS(Ag), preliminary investigation of the radioluminescence characterization of Zinc oxide (ZnO) for alpha particle detection was performed. Materials and Methods: The scintillation properties of ZnO films were tested using alpha sources                &nbsp...

متن کامل

Photon dosimetry based on selective data sampling for the NaI(TL) detector

Radiation detection is essential for determining of radiation dose. Depend on the detector and dosimetry method, detection process is performed in different levels. Pulse counting is the first level of detection. Typically, the output of a radiation detector for determining value of the radiation dose cannot be used directly. Through changing the response function or the readout detector, is tr...

متن کامل

A first comparison of the responses of a He-based fast-neutron detector and a NE-213 liquid-scintillator reference detector

A first comparison has been made between the pulse-shape discrimination characteristics of a novel He-based pressurized scintillation detector and a NE-213 liquid-scintillator reference detector using an Am/Be mixed-field neutron and gamma-ray source and a high-resolution scintillation-pulse digitizer. In particular, the capabilities of the two fast neutron detectors to discriminate between neu...

متن کامل

An educational distributed Cosmic Ray detector network based on ArduSiPM

The advent of microcontrollers with enough CPU power and with analog and digital peripherals makes possible to design a complete particle detector with relative acquisition system around one microcontroller chip. The existence of a world wide data infrastructure as internet allows for devising a distributed network of cheap detectors capable to elaborate and send data or respond to settings com...

متن کامل

A Microcontroller Based Digital Vector Impedance Meter With Sampling Reduction

Abstract This paper proposed the microcontroller based vector impedance meter, which can be used to measure unidentified impedance of the system. The microcontroller read only four samples from two voltage signals, the first voltage is proportional to the voltage across the impedance while the second voltage is proportional to the current passing through it. A novel algorithm is then used to ge...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014