Tissue oximetry: a comparison of mean values of regional tissue saturation, reproducibility and dynamic range of four NIRS-instruments on the human forearm

نویسندگان

  • Simon Hyttel-Sorensen
  • Line C. Sorensen
  • Joan Riera
  • Gorm Greisen
چکیده

We compared absolute values of regional tissue hemoglobin saturation (StO(2)), reproducibility, and dynamic range of four different instruments on the forearm of adults. The sensors were repositioned 10 times on each subject. Dynamic range was estimated by exercise with subsequent arterial occlusion. Mean StO(2) was 70.1% ± 6.7 with INVOS 5100, 69.4% ± 5.0 with NIRO 200 NX, 63.4% ± 4.5 with NIRO 300, and 60.8% ± 3.6 with OxyPrem. The corresponding reproducibility S(w) was 5.4% (CI 4.4-6.9), 4.4% (CI 3.5-5.2), 4.1% (CI 3.3-4.9), and 2.7% (CI 2.2-3.2), respectively. The dynamic ranges ΔStO(2) were 45.0%, 46.8%, 44.8%, and 27.8%, respectively. In conclusion, the three commercial NIRS instruments showed different absolute values, whereas reproducibility and dynamic range were quite similar.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility of long-term cerebral and peripheral regional tissue oxygen saturation measurements.

The aim of this study was to analyse the feasibility of long-term measurements of cerebral (crSO2) and peripheral (prSO2) regional tissue oxygen saturation on the first day of life by determining the amount of artefacts and their influence on rSO2. Near infrared spectroscopy (NIRS) measurements were performed fronto-parietal left (crSO2) and on the right forearm (prSO2). Arterial oxygen saturat...

متن کامل

Impact of extracranial contamination on regional cerebral oxygen saturation: a comparison of three cerebral oximetry technologies.

BACKGROUND Cerebral oximetry is a noninvasive technology using near-infrared spectroscopy (NIRS) to estimate regional cerebral oxygen saturation. Although NIRS cerebral oximetry is being increasingly used in many clinical settings, interdevice technologic differences suggest potential variation in the ability to accurately acquire brain oxygenation signals. The primary objective of this study w...

متن کامل

Correlation of intraoperative renal near infrared spectroscopy with the development of acute kidney injury in adult patients undergoing cardiac surgery using cardiopulmonary bypass

Introduction: The present study aimed to correlate renal oximetry near-infrared spectroscopy (NIRS) values with conventional non-invasive biomarkers for the early detection of acute kidney injury (AKI) in adult patients undergoing cardiac surgery using cardiopulmonary bypass (CPB). Accordingly, renal NIRS can be employed as a trending device for the prevention of AKI developmen...

متن کامل

Clinical use of cerebral oximetry in extremely preterm infants is feasible.

INTRODUCTION The research programme Safeguarding the Brains of our smallest Children (SafeBoosC) aims to test the benefits and harms of cerebral near-infrared spectroscopy (NIRS) oximetry in infants born before 28 weeks of gestation. In a phase II trial, infants will be randomised to visible cerebral NIRS oximetry with pre-specified treatment guidelines compared to standard care with blinded NI...

متن کامل

Effect of Skin Pigmentation on Near Infrared Spectroscopy

The purpose of this study was to determine the effects of skin pigmentation regarding Near Infrared Spectroscopy (NIRS) tissue oxygen saturation values (StO2). The study examined NIRS values in individuals with varying skin pigmentation on the anterior compartment of the lower leg and volar forearm to determine if correlation exists among three NIRS devices, the EQUANOX, Casmed, and INVOS. Skin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2011