In situ determination of trace elements in Fucus spp. by field-portable-XRF.

نویسندگان

  • Andrew Turner
  • Hiu Poon
  • Alex Taylor
  • Murray T Brown
چکیده

Fresh and freeze-dried sample sections of the coastal macroalgae, Fucus serratus and F. vesiculosus, and the brackish water macroalga, F. ceranoides, have been analysed for trace elements by field-portable-X-ray fluorescence (FP-XRF) spectrometry using a Niton XL3t in a low density mode with thickness correction. When analysed fresh in a laboratory accessory stand for a period of 200 seconds, As, Br, Fe and Zn were registered in the apex, mid-frond and lower stipe of all species, with detection limits of a few μg g-1 (As) or a few tens of μg g-1 (Br, Fe, Zn); when analysed dry under the same conditions, concentrations returned were systematically higher and Cu and Pb were detected in a number of F. ceranoides sections. Concentrations arising from both approaches on a dry weight basis were highly correlated, with deviations from unit slope attributed to the absorption of fluorescent X-rays by internal and surficial water when analysed fresh. With algorithms correcting for the effects of water on mass and X-ray absorption, sections of F. vesiculosus and F. ceranoides were analysed in situ with the XRF connected to a mobile stand and laptop. Dry weight concentrations returned for As and Zn were significantly correlated with respective concentrations subsequently determined by ICP-MS following acid digestion and with a slope close to unity; lower concentrations of Fe returned by ICP were attributed to the incomplete acid digestion of silt particles that evaded an initial cleaning step, while Br concentrations could not be verified independently because of loss of volatile forms during digestion. The in situ determination of trace elements in fucoids by FP-XRF provides a rapid and non-destructive means of monitoring environmental quality and identifying hot-spots of contamination, and enables a research strategy to be developed iteratively that is informed by immediate results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Elimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry

A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...

متن کامل

Ionic Liquid-based Ultrasound-assisted In-situ Solvent Formation Microextraction and High-performance Liquid Chromatography for the Trace Determination of Polycyclic Aromatic Hydrocarbons in Environmental Water Samples

A green and efficient ionic liquid-based ultrasound-assisted in-situ solvent formationmicroextraction (IL-UA-ISFME) in combination with high-performance liquid chromatographyultravioletdetection (HPLC-UV) has been successfully developed for the trace determination offive selected polycyclic aromatic hydrocarbons (PAHs) in environmental water samples. In thismethod, a hydrophobic ionic liquid (1...

متن کامل

Field detection of CO and CH4 by NIR 2f modulation laser spectroscopy

  A novel compact fiber-coupled NIR system based on a DFB diode laser source is employed as a portable and sensitive gas sensor for trace detection of combustion pollutant molecules. We demonstrate the performance of such an NIR gas sensor by tracing the absorption lines of CO and CH4 using 2f-WMS technique at moderate temperature of T ~ 600°C in the recuperator channel of an industrial furnace...

متن کامل

Trace Determination of Duloxetine in Human Plasma by a Novel Ionic Liquid-Based Ultrasound-Assisted In Situ Solvent Formation Microextraction and High-Performance Liquid Chromatography

For the first time, a novel and efficient ionic liquid-based ultrasound-assisted in-situ solvent formation microextraction (IL-UA-ISFME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) has been successfully developed for the determination of duloxetine (DLX) in human plasma. Herein, an environmentally-friendly hydrophobic ionic liquid (1-butyl-3-methylimidaz...

متن کامل

Development and optimisation of a portable micro-XRF method for in situ multi-element analysis of ancient ceramics.

Non-destructive analysis of cultural objects by micro-XRF spectrometry is an advantageous multi-element technique that has rapidly developed during the past few years. Portable instruments contribute significantly to the in situ analysis of valuable cultural objects, which cannot be transported to the laboratory. Ancient ceramics are the most common archaeological findings and they carry a sign...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Science of the total environment

دوره 593-594  شماره 

صفحات  -

تاریخ انتشار 2017