Distinguishing pial and laminar gradient-echo BOLD signals at 7 Tesla

نویسندگان

  • P. J. Koopmans
  • S. Orzada
  • M. Barth
  • D. G. Norris
چکیده

Introduction With high field scanners and multi-channel coil arrays becoming more readily available, high resolution fMRI methods may be capable of detecting neural responses at the laminar level. First results in animals indicate that gradient-echo (GE) is not able to depict laminar activation [1-4] and this has been attributed to the large BOLD contribution of the pial veins corrupting the laminar activation profiles. Spin-echo (SE) studies on the other hand have been able to depict layer specific activation in animals [1-3]. At high field strengths (7T and above), the largest contribution to the SE-BOLD effect originates from the capillaries and hence SE is thought to be the method of choice for high resolution fMRI. In this study we show that GE is capable of depicting laminar activation when using a sequence with a high resolution and a high degree of anatomical trueness (i.e. no distortion). When these conditions are met, veins can be separated from the laminar response based upon their position alone and one can benefit from the superior sensitivity and reduced SAR of the GE method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Echo time dependence of laminar BOLD activation at 7 Tesla

Introduction We present a multi-echo fMRI study at 7 T with 0.75 mm isotropic voxels and TEs ranging from 4.8 to 56 ms. This makes it possible to determine T2 at an unprecedented spatial scale making it possible to assess the local influence of myelinisation and vascularisation. As expected [1], the signal superficial to the cortex decays non-mono-exponentially because of a mixed compartment of...

متن کامل

BOLD fMRI signal characteristics of S1- and S2-SSFP at 7 Tesla

OBJECT To compare the BOLD fMRI signal characteristics at in the cortex and on the pial surface for a non-balanced steady-state free precession sequence (nb-SSFP) at 7 T. MATERIALS AND METHODS A multi-echo nb-SSFP sequence was used for high resolution fMRI at 7 T. Two S1 (S(+)) echoes at different echo times were acquired together with an S2 (S(-)) echo. The primary visual cortex (V1) was exa...

متن کامل

Neural interpretation of blood oxygenation level-dependent fMRI maps at submillimeter columnar resolution.

Whether conventional gradient-echo (GE) blood oxygenation-level-dependent (BOLD) functional magnetic resonance imaging (fMRI) is able to map submillimeter-scale functional columns remains debatable mainly because of the spatially nonspecific large vessel contribution, poor sensitivity and reproducibility, and lack of independent evaluation. Furthermore, if the results from optical imaging of in...

متن کامل

Unexpected BOLD behavior at 11.7 Tesla: A Comparison of Experimental Data with the Integrative BOLD Signal Model

Introduction: It is generally accepted that the contrast of BOLD response increases with higher magnetic field strength [1]. However, in experimental and clinical studies it was shown that the intravascular component (IV) of the BOLD effect disappears for magnetic fields higher 4.0 Tesla, which is due to very short blood T2 at higher fields. Extravascular components (EV) are still expected to i...

متن کامل

Quantifying the spatial resolution of the gradient echo and spin echo BOLD response at 3 Tesla.

The blood oxygen level dependent (BOLD) response, as measured with fMRI, offers good spatial resolution compared to other non-invasive neuroimaging methods. The use of a spin echo technique rather than the conventional gradient echo technique may further improve the resolution by refocusing static dephasing effects around the larger vessels, so sensitizing the signal to the microvasculature. In...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008