Blood flow quantification in adults by phase-contrast MRI combined with SENSE--a validation study.

نویسندگان

  • Philipp Beerbaum
  • Hermann Körperich
  • Jürgen Gieseke
  • Peter Barth
  • Matthias Peuster
  • Hans Meyer
چکیده

PURPOSE To evaluate the feasibility of rapid free-breathing phase-contrast MRI (PC-MRI) at different in-plane resolutions combined with sensitivity encoding (SENSE) for flow quantification in the great arteries in healthy adult volunteers. METHODS In 13 volunteers (mean age 33.0 +/- 7.4 years), blood flow rates in the pulmonary artery (Qp), ascending aorta (Qs), and flow ratio Qp/Qs were determined by PC-MRI with SENSE reduction-factor 2 and 3 (SF-2, SF-3). Additionally, we used PC-MRI with higher spatial in-plane resolution (1.6 x 2.1 mm vs. 2.3 x 3.1 mm) with/without SF-3. Standard (= reference) PC-MRI, which used two excitations (NEX=2), was compared with PC-MRI sequences with NEX=1. RESULTS Reduction of signal averages and application of SENSE accelerated flow measurements by a factor of 3.8 (5.5) using PC-MRI with SF-2 (SF-3): Scan time was 36 sec (SF-2) and 25 sec (SF-3) at average heart rate of 69/min. The mean Qp/Qs by reference PC-MRI was 1.03 +/- 0.07 (range, 0.89-1.16), and 1.0 +/- 0.11 (range, 0.86-1.24) by PC-MRI + SF-3, respectively. For blood flow rate through the pulmonary artery and aorta, and for Qp/Qs ratio, we found differences of -3% to +4%. The lower limits of agreement (mean - 2 SD) ranged between -14% and -21%, and upper limits (mean + 2 SD) between +9% and +30%, demonstrating clinically acceptable agreement with standard PC-MRI (Bland-Altman analysis). PC-MRI at higher in-plane resolution both with/without SENSE yielded slightly smaller aortic and pulmonary flows (mean differences 5% to 7%, p < 0.05). CONCLUSIONS. In adults, PC-MRI may be safely combined with SENSE to reduce scan time for a quantitative flow measurement in the great arteries to "30 seconds. High in-plane resolution was not advantageous.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid left-to-right shunt quantification in children by phase-contrast magnetic resonance imaging combined with sensitivity encoding (SENSE).

BACKGROUND Parallel imaging by sensitivity encoding (SENSE) may considerably reduce scan time in MRI. For rapid flow quantification in children with congenital heart disease, we evaluated phase-contrast MRI (PC-MRI) techniques combined with SENSE. METHODS AND RESULTS In 22 pediatric patients (mean age, 7.2+/-6.2 years) with cardiac left-to-right shunt, blood flow rate in the pulmonary artery ...

متن کامل

Rapid Left-to-Right Shunt Quantification in Children by Phase-Contrast Magnetic Resonance Imaging Combined With Sensitivity Encoding

Background—Parallel imaging by sensitivity encoding (SENSE) may considerably reduce scan time in MRI. For rapid flow quantification in children with congenital heart disease, we evaluated phase-contrast MRI (PC-MRI) techniques combined with SENSE. Methods and Results—In 22 pediatric patients (mean age, 7.2 6.2 years) with cardiac left-to-right shunt, blood flow rate in the pulmonary artery (Qp)...

متن کامل

Comparison of 4D flow and 2D PC MRI blood flow quantification in children and young adults with congenital heart disease

Background Echocardiography (echo) is the primary imaging modality for assessment of aortic and pulmonary blood flow velocities. 2D phase contrast (PC) MRI provides better access to all segments of the aortic and pulmonary system and is considered the standard for evaluating blood flow. Both techniques are limited by velocity analysis in 2D planes and by single-direction velocity measurement wh...

متن کامل

Flow volume and shunt quantification in pediatric congenital heart disease by real-time magnetic resonance velocity mapping: a validation study.

BACKGROUND Flow quantification in real time by phase-contrast MRI (PC-MRI) may provide unique hemodynamic information in congenital heart disease, but available techniques have important limitations. We sought to validate a novel real-time magnetic resonance flow sequence in children. METHODS AND RESULTS In 14 pediatric patients (mean age 5.2+/-2.0 years) with cardiac left-to-right shunt, pul...

متن کامل

Summary and General Discussion

The research described in this thesis was aimed at improving velocity measurements of blood flow in the ventricles using cardiac Magnetic Resonance Imaging. The incentive for this work was the clinical need to quantify the severity of mitral valve regurgitation in an absolute sense. MRI is an important non-invasive diagnostic tool in cardiology. Besides imaging the anatomy, the MR phase contras...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance

دوره 7 2  شماره 

صفحات  -

تاریخ انتشار 2005