The quick-implantable-defibrillator trial.

نویسندگان

  • Dietmar Bänsch
  • Hans Kottkamp
  • Gerian Grönefeld
  • Jürgen Vogt
  • Carsten Israel
  • Dirk Böcker
  • Gerd Hindricks
  • Karl-Heinz Kuck
چکیده

AIMS Earlier ICD therapy included an electrophysiological study (EPS), an extensive defibrillation threshold test (DFT), and a pre-discharge test. Now that ICD-therapy is widely accepted, an EPS is no longer performed in most patients, extensive DFT-tests have been reduced to a minimum of two effective shocks and discharge tests have been discarded in most centres. However, it has never been demonstrated prospectively that this simplification is safe. METHODS AND RESULTS The Quick-Implantable-Defibrillator (Quick-ICD) Trial was a prospective multi-centre trial, which randomized patients, who had survived a cardiac arrest (SCD) or an unstable ventricular tachycardia (VT), to two different clinical strategies: (a) The extensive strategy included an EPS, an extensive DFT-test, and a pre-discharge test; (b) In the simplified approach (quick strategy) the ICD was implanted without an EPS and a pre-discharge test. Two effective shocks during implantation at 21 J were sufficient. The primary endpoint of this trial was a cluster of adverse events related to the diagnostic approach and to ICD-therapy. One hundred and ninety patients were included, 97 randomized to the extensive-, 93 to the quick strategy. Mean follow-up was 12 +/- 7 months. Twenty-seven patients reached the endpoint in the quick group and 32 in the extensive group. During follow-up, the event-free survival was equal in the two study arms (test for equivalence, P = 0.0044). The initial hospital stay was significantly shorter in the quick population (8.4 +/- 4.7 vs. 11.2 +/- 7.4 days, P = 0.004) CONCLUSION It is safe and cost-effective to implant an ICD without an EPS, an extensive DFT-, and a pre-discharge test in carefully selected patients after survived SCD or unstable VTs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

زندگی با دفیبریلاتور قابل کاشت: یک مطالعه پدیده‌شناسی

  Background & Aim: Implantable Cardioverter Defibrillator is the most effective treatment for cardiac dysrhythmias. Having such life-saving device is the unique experience with important changes in the patient’ life. Understanding of these experiences can lead to success in treatment and follow- up.This study aimed to understand the experiences of patients with Implantable Cardioverter Defibri...

متن کامل

The effect of education based on Orem’s self-care model on emotional reactions in patients with Implantable Cardioverter Defibrillator (ICD)

Abstract Aim. The purpose of this study was to examine the effect of education based on Orem’s self-care model on emotional reactions in people with Implantable Cardioverter Defibrillator (ICD). Background. ICD shock is unpredictable and associated with physical pain. After receiving shock, some patients find serious psychological problems such as anxiety, depression and stress. According to Or...

متن کامل

تأثیر آموزش مبتنی بر الگوی خودمراقبتی اورم بر توان خودمراقبتی بیماران دارای دفیبریلاتور قلبی قابل کاشت (ICD)

  Background & Aim: Several studies have shown that the self-care activity of patients with implantable cardioverter defibrillator is inadequate. This study was conducted to assess the effect of an educational program based on the Orem’s self-care model in self-care ability of the patients .   Methods & Materials: This clinical trial was conducted among 66 patients with implantable cardiove...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 9 12  شماره 

صفحات  -

تاریخ انتشار 2007