Three-Dimensional Digital Capture of Head Size in Neonates – A Method Evaluation

نویسندگان

  • Sascha Ifflaender
  • Mario Rüdiger
  • Arite Koch
  • Wolfram Burkhardt
چکیده

INTRODUCTION The quality of neonatal care is mainly determined by long-term neurodevelopmental outcome. The neurodevelopment of preterm infants is related to postnatal head growth and depends on medical interventions such as nutritional support. Head circumference (HC) is currently used as a two-dimensional measure of head growth. Since head deformities are frequently found in preterm infants, HC may not always adequately reflect head growth. Laser aided head shape digitizers offer semiautomatic acquisition of HC and cranial volume (CrV) and could thus be useful in describing head size more precisely. AIMS 1) To evaluate reproducibility of a 3D digital capture system in newborns. 2) To compare manual and digital HC measurements in a neonatal cohort. 3) To determine correlation of HC and CrV and predictive value of HC. METHODS Within a twelve-month period data of head scans with a laser shape digitizer were analysed. Repeated measures were used for method evaluation. Manually and digitally acquired HC was compared. Regression analysis of HC and CrV was performed. RESULTS Interobserver reliability was excellent for HC (bias-0.005%, 95% Limits of Agreement (LoA) -0.39-0.39%) and CrV (bias1.5%, 95%LoA-0.8-3.6%). Method comparison data was acquired from 282 infants. It revealed interchangeability of the methods (bias-0.45%; 95%LoA-4.55-3.65%) and no significant systematic or proportional differences. HC and CrV correlated (r(2) = 0.859, p<0.001), performance of HC predicting CrV was poor (RSD ±24 ml). Correlation was worse in infants with lower postmenstrual age (r(2) = 0.745) compared to older infants (r(2) = 0.843). DISCUSSION The current practice of measuring HC for describing head growth in preterm infants could be misleading since it does not represent a 3D approach. CrV can vary substantially in infants of equal HC. The 3D laser scanner represents a new and promising method to provide reproducible data of CrV and HC. Since it does not provide data on cerebral structures, additional imaging is required.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Full scatter convolution algorithm based Treatment Planning System performance in the presence of inhomogeneities using three-dimensional film dosimetry

Introduction: Inclusion of inhomogeneities such as air-filled cavities in the head and neck treatment fields may result in potential dosimetric disagreement which was caused by electronic disequilibrium. Most of treatments planning systems (TPS) are not able to predict dose distribution of inhomogeneous regions accurately. EBT2 films are used frequently in radiotherapy quality ass...

متن کامل

Evaluation and prognosis of neonates with asphyxia treated by hypothermia

Background: Asphyxia is a perinatal accident with a high mortality rate, therapeutic hypothermia in both head or whole body was suggested as effective therapeutic methods. In this study, we compare these methods in neonates with asphyxia.Methods and Materials: 16 neonates with asphyxia in two hospitals including Alzahra(head hypothermia) and Taleghani hospital (total body hypothermia) went unde...

متن کامل

Mechanical performance of three-dimensional bio- nanocomposite scaffolds designed with digital light processing for biomedical applications

Introduction: The need for biocompatible and bioactive scaffolds to accelerate the regeneration and repair of fractured bones has been considered for bone tissue engineering applications during recent decades. The new methods were developed to produce scaffolds to improve the tissue quality, size of cavities, control the porosity and increase the scaffold compressive strength u...

متن کامل

Evaluation of Seasonal Variation of Anthropometric Parameters in Newborns Shariati Hospital in 2004-5

Objective: birth body size is an indicator of intrauterine growth and important in later health. this study was performed to assess seasonal variation of birth body size in a group of Iranian newborn. Patients and method: in a retrospective design, Hospital records of 2034 of singleton newborn with gestational age >37 week and no malformation or neonatal disorder, was assessed sex delivery type...

متن کامل

Three-dimensional Volumetric Ultrasonography of Enlarged Adrenal Gland in Dog

Objective: Detection and evaluation of adrenal glands are complex problems in conventional ultrasonography in dogs. Using three-dimensional (3D) ultrasonography (US) in adrenal gland volume evaluation can add new potential for further adrenal studies. Design: Descriptive study Animals: a total of 10 mix breed dogs Procedures: The dogs underwent two dimensional (2D) and 3D US of the adrenal g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013