The Effects of Instrument Handle Design on Forearm Muscle Activity During Scaling by Dental Hygienists
نویسندگان
چکیده
EFFECTS OF INSTRUMENT HANDLE DESIGN ON FOREARM MUSCLE ACTIVITY DURING SCALING BY DENTAL HYGIENISTS Jessica Rae Suedbeck Old Dominion University, 2016 Director: Professor Susan Lynn Tolle Purpose: The purpose of this study was to determine the effects of 4 different commercially available instrument handle designs (A. 16 grams and 12.7 mm diameter; B. 23 grams and 11.1 mm diameter; C. 21 grams and 7.9 mm diameter; D. 18 grams and 6.35 mm diameter) on the muscle activity of four forearm muscles during a simulated scaling experience. Methods: A convenience sample of 27 dental hygienists used a Columbia 13/14 curet with four different instrument handles to scale artificial calculus. While scaling, each participant’s muscle activity was measured using surface electromyography (sEMG). Participants completed an end user opinion survey. Results: Similar muscle activity was generated when scaling with instruments at 16, 18, and 21 grams with varying diameter handles. Instrument B generated significantly more muscle activity when compared to each of the other 3 instrument handle designs (p=0.001, p=0.002, p=0.039). Additionally, the lower left quadrant displayed significantly less muscle activity during scaling than the right quadrants (p=0.026, p=0.000), although no significant interaction effect was found with instruments within quadrants. Most participants (62.96%) preferred instrument A, which was rated more comfortable based on weight when compared to the other instruments tested (z=2.643, p=0.008; z=3.708, p=0.000; z=3.819, p=0.000). The smallest diameter instrument was rated significantly less comfortable (A. z=4.398, p=0.000; B. z=4.023,p=0.000; C. z=3.333, p=0.001). Conclusions: Instrument handle design has a significant effect on forearm muscle activity when performing scaling in a simulated environment. The heaviest instrument produced the highest muscle activity. Similar amounts of muscle activity were produced by instruments weighing between 16 and 21 g. Participants’ instrument preferences were more affected by handle diameter than weight. The need for further research is needed to determine the impact of these results on arm muscle load related to risk of cumulative trauma disorders in a real-world setting.
منابع مشابه
The effect of tool handle shape on hand muscle load and pinch force in a simulated dental scaling task.
Work-related upper extremity musculoskeletal disorders, including carpal tunnel syndrome, are prevalent among dentists and dental hygienists. An important risk factor for developing these disorders is forceful pinching which occurs during periodontal work such as dental scaling. Ergonomically designed dental scaling instruments may help reduce the prevalence of carpal tunnel syndrome among dent...
متن کاملComparison of Corded and Cordless Handpieces on Forearm Muscle Activity, Procedure Time and Ease of Use during Simulated Tooth Polishing.
PURPOSE Dental professionals suffer from a high prevalence of work-related musculoskeletal disorders (MSD). Dental hygienists in particular have a high prevalence of pain in the forearms and hands. The objective of this study was to compare 1 cordless handpiece to 2 corded handpieces during simulated tooth polishing in terms of the muscle loads (recorded as electromyography (EMG) activity), dur...
متن کاملEffects of 5 different finger rest positions on arm muscle activity during scaling by dental hygiene students.
PURPOSE This study was conducted to determine the effects of 5 different finger rest positions: opposite arch, standard intraoral, basic extraoral, cross arch, and finger on finger on the muscle activity of 4 forearm muscles (extensor carpi radialis longus, flexor carpi ulnaris, biceps brachii, and pronator teres) during a simulated periodontal scaling experience. METHODS A convenience sample...
متن کاملComparison of muscle activity associated with structural differences in dental hygiene mirrors.
PURPOSE Ergonomic studies suggest that the commonly used pinch grasp, held in a static position, is a contributing factor for dental Hygienists' development of work-related musculoskeletal disorders (WMSDs) such as carpal tunnel syndrome (CTS), Trigger Thumb, de Quervain's stenosing tenosynovitis, and carpometacarpal (CMC) osteoarthritis. The pinch grasp is commonly used by the dental hygienist...
متن کاملEffects of the Different Screwdriver Handle Sizes on the Forearm Muscles Activities and Wrist Motion during Screw-driving Work
[Purpose] This study investigated the difference screwdriver handle size has on forearm muscle activities and wrist motion during screw-driving work. [Subjects] Fourteen males aged 20-30 years, were recruited. [Methods] We measured the forearm muscle activities using a MP 150 System and wrist motion using a 3D motion system. The subjects performed screw-driving tasks with different screwdriver ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2016