The accuracy of the Acuros XB algorithm in external beam radiotherapy – a comprehensive review

نویسنده

  • Jarkko Ojala
چکیده

The accuracy of dose calculation algorithms has been a topic of interest among the radiotherapy community throughout last decades. On one hand the advancements in computers and algorithms has improved the accuracy, but on the other hand the developments in other parts of treatment process, in treatment delivery techniques and in treatment devices have always pushed the requirements to the next level. In this review article a comprehensive overview on the accuracy of a new type ‘c’ dose calculation algorithm, the Acuros XB (AXB) algorithm (Varian Medical Systems, Inc., Palo Alto, CA, USA), is provided. All the articles that have applied the AXB algorithm in terms of external beam radiotherapy are included and the research frames with reported deviations to reference methods are described. For the homogeneous water phantoms the reported accuracy was from 1% to 2%, being of similar level for heterogeneous phantoms, in rare occasions lower. In anthropometric and anthropomorphic phantoms the mean deviations were about 2% and slightly larger for single points and/or small regions. With patient plans the reported average discrepancies were less than from 3% to 5%. Almost without exceptions, the algorithm has proven to perform better than other existing commercial dose calculation algorithms. The number of such papers, in which the AXB algorithm is the only dose determination method, is already notable, which indicates that the accuracy of the algorithm is trusted for reference use and it also, with reported dosimetric results, implies that the AXB algorithm has reached its maturity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric accuracy of the Acuros XB and Anisotropic analytical algorithm near interface of the different density media for the small fields of a 6- MV flattening-filter-free beam

Background: This study was conducted to assess the accuracy of dose calculation near the air-phantom interface of a heterogeneous phantom for Acuros XB (AXB) and Anisotropic Analytical Algorithm (AAA) algorithm of a           6-MV flattening-filter-free beam, compared with film measurements. Materials and Methods: A phantom included air gap was ...

متن کامل

Using Varian Photon Beam Source Model for Dose Calculation of Small Fields

The use of small fi elds in radiotherapy techniques has increased substantially, in particular in stereotactic treatments and large uniform or nonuniform fi elds that are composed of small fi elds, such as for intensity-modulated radiation therapy (IMRT). This clinical perspective will focus on an experimental evaluation of the dose calculation accuracy of the anisotropic analytical algorithm (...

متن کامل

Clinical implementation and evaluation of the Acuros dose calculation algorithm

PURPOSE The main aim of this study is to validate the Acuros XB dose calculation algorithm for a Varian Clinac iX linac in our clinics, and subsequently compare it with the wildely used AAA algorithm. METHODS AND MATERIALS The source models for both Acuros XB and AAA were configured by importing the same measured beam data into Eclipse treatment planning system. Both algorithms were validated...

متن کامل

On the dosimetric impact of inhomogeneity management in the Acuros XB algorithm for breast treatment

BACKGROUND A new algorithm for photon dose calculation, Acuros XB, has been recently introduced in the Eclipse, Varian treatment planning system, allowing, similarly to the classic Monte Carlo methods, for accurate modelling of dose deposition in media. Aim of the present study was the assessment of its behaviour in clinical cases. METHODS Datasets from ten breast patients scanned under diffe...

متن کامل

A Review on the Use of Grid-Based Boltzmann Equation Solvers for Dose Calculation in External Photon Beam Treatment Planning

Deterministic linear Boltzmann transport equation (D-LBTE) solvers have recently been developed, and one of the latest available software codes, Acuros XB, has been implemented in a commercial treatment planning system for radiotherapy photon beam dose calculation. One of the major limitations of most commercially available model-based algorithms for photon dose calculation is the ability to ac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014