Simultaneous multislice imaging with slice-multiplexed RF pulses.

نویسندگان

  • K J Lee
  • J M Wild
  • P D Griffiths
  • M N J Paley
چکیده

A method for simultaneous multislice imaging is presented that uses a multislice RF pulse that imparts a different linear phase profile to each slice. During readout, slices are unaliased by using extra slice-select gradient lobes, which rephase and dephase individual slices one at a time. Compared to other simultaneous slice methods, this method avoids distortion by slice-select gradients, and does not require extra views or additional hardware. However, because one echo per slice is required, the method requires a longer read period. This can cause non-ideal rephasing of the individual slices due to susceptibility gradients, which manifests itself as crosstalk between slices. There is also a concomitant increase in the minimum TR of the sequence. The method is demonstrated with phantom and in vivo images using gradient-echo and spin-echo versions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design of slice multiplexed pulses for simultaneous multislice imaging

K. J. Lee, M. N. Paley, P. D. Griffiths, J. M. Wild Academic Radiology, University of Sheffield, Sheffield, South Yorkshire, United Kingdom Introduction: Recently we introduced a new method for simultaneous multislice imaging [1,2]. The main idea is a novel rf pulse that gives each slice a different linear phase profile. Then, when one slice is rephased by the slice gradient, the others are dep...

متن کامل

Wideband Parallel Imaging

Human lower limb images were successfully acquired with an acceleration rate of up to 8x by using wideband parallel imaging. The non-uniform multislice profile problem of this technique was successfully compensated to enhance the image quality of the outer slices. Also the signal-to-noise ratio (SNR) of this ultra fast imaging technique, wideband parallel imaging, was verified to be similar wit...

متن کامل

Simultaneous multislice (SMS) imaging techniques

Simultaneous multislice imaging (SMS) using parallel image reconstruction has rapidly advanced to become a major imaging technique. The primary benefit is an acceleration in data acquisition that is equal to the number of simultaneously excited slices. Unlike in-plane parallel imaging this can have only a marginal intrinsic signal-to-noise ratio penalty, and the full acceleration is attainable ...

متن کامل

High‐resolution gradient‐recalled echo imaging at 9.4T using 16‐channel parallel transmit simultaneous multislice spokes excitations with slice‐by‐slice flip angle homogenization

PURPOSE In order to fully benefit from the improved signal-to-noise and contrast-to-noise ratios at 9.4T, the challenges of B1+ inhomogeneity and the long acquisition time of high-resolution 2D gradient-recalled echo (GRE) imaging were addressed. THEORY AND METHODS Flip angle homogenized excitations were achieved by parallel transmission (pTx) of 3-spoke pulses, designed by magnitude least-sq...

متن کامل

Single-shot line scan imaging using stimulated echoes.

A new high-speed MRI method is described for single-shot line scan imaging (LSI) based on stimulated echoes (STE). To allow for multislice imaging, the technique comprises a series of slice-selective preparation pulses (each corresponding to the first RF pulse of a STE sequence), a slab-selective refocusing pulse (second RF pulse), and multiple line-selective read pulses (third RF pulses). An a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 54 4  شماره 

صفحات  -

تاریخ انتشار 2005