Determination of oxolinic acid in cow's milk and human urine by means of a single-use phosphorimetric sensor.
نویسندگان
چکیده
A single-use phosphorimetric drop plane sensor for the determination of oxolinic acid (OXA) is proposed. The sensor was formed by a 30x16 mm(2) rectangular strip of Mylar type polyester as solid support that contained a circular sensing zone, 6 mm in diameter and 20 mum in thickness, formed by PVC plasticized with tributylphosphate adhered to its surface. When the strip was introduced for 1 hour into a sample solution, the analyte was retained in the sensing zone, making it possible to directly measure the phosphorescence intensity emitted by the OXA in the solid phase, at lambda(exc)=330 nm and lambda(em)=449 nm. The variables that affect the construction of the sensor have been studied, along with the experimental variables that influence the fixation of the analyte in the sensor. The method's detection limit was 0.01 mg l(-1) with an applicable concentration range from 0.04 to 1.50 mg l(-1) and a repeatability of 2.6% at the concentration range of 0.8 mg l(-1). The method was applied to samples of human urine and cows' milk, with recovery percentages ranging between 97.6 and 108.7%.
منابع مشابه
Single-use phosphorimetric sensor for the determination of nalidixic acid in human urine and milk.
A single-use phosphorimetric sensor to determine the germicide nalidixic acid is proposed. The sensing action is based on the absorption of the analyte into the sensing zone and the subsequent measurement of the phosphorescence intensity emitted by the analyte fixed in the sensor. This plane drop sensor is made up of a 3 x 1.6 cm sheet of the polyester Mylar as solid support, and a circular fil...
متن کاملIodine Determination in Raw Cow's Milk in Iran
Iodine is an essential trace element in the human diet. The following work presents the latest information concerned with iodine determination in raw milk, in Iran. Iodine content of milk was determined by Sandell-Kolthoff method where the samples were taken from Holstein dairy cows, in Shahrkord, the central part of Iran. Thirty six samples were taken from transportation tanks in semi industri...
متن کاملSensitive Voltammetric Determination of Acetaminophen at Poly(4-vinyl pyridine)/Graphene Composite Modified Electrode
This study demonstrates the use of a selective and sensitive voltammetric sensor for determination of acetaminophen (AC). This was performed by modifying a glassy carbon electrode with composite film of poly(4-vinylpyridine) and graphene sheet (P4VP/GR-GCE). The redox peak currents of AC increased significantly at P4VP/GR-GCE. The result was achieved by the synergistic effect of combined elect...
متن کاملAn efficient platform based on cupper complex-multiwalled carbon nanotube nanocomposite modified electrode for the determination of uric acid
A new voltammetric sensor for determination of uric acid (UA) by Cuppercomplex- multiwalled carbon nanotube (Cu-complex-CNT) nanocomposite modifiedcarbon paste electrode (CPE) is reported. The electrocatalytic behavior of theCu-complex-CNT nanocomposite modified CPE was studied in pH 2.0 phosphatebuffer solution by chronoamperometry (CA) and cyclic voltammetry (CV) in th...
متن کاملDetermination of aflatoxin M1 levels in raw milk samples using ELISA and high-performance liquid chromatography in Qazvin, Iran
Use of raw milk and dairy products containing aflatoxin M1 (AFM1) has led to concern inconsumers. The present study determined the AFM1 in raw cow's milk in Qazvinprovince. In this research, 170 raw cow's milk were collected from dairy farm, dairyfactories, milk collection centers, and milk supply centers in Qazvin province during coldseasons in 2013, and all samples were examined for AFM1. The...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Talanta
دوره 60 2-3 شماره
صفحات -
تاریخ انتشار 2003