Comparison of Y1 mouse adrenal cell and coagglutination assays for detection of Escherichia coli heat labile enterotoxin.

نویسندگان

  • P A Chapman
  • C M Daly
چکیده

A commercial coagglutination assay (COA; Phadebact LT-ETEC) was compared with a Y1 mouse adrenal cell assay for detecting the heat labile enterotoxin of Escherichia coli. Of four different media evaluated for use with the COA, only one (modified blood agar) gave a positive result with all strains known to produce heat labile enterotoxin. With modified blood agar, the COA detected 74 (85%) of 87 such strains. Eighty six strains negative by cell culture assay were also negative by COA, and one strain positive by COA could not be confirmed by cell culture. The Phadebact LT-ETEC kit provides a simple, sensitive, and economical method for detecting E coli heat labile enterotoxin.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative study of synthetic oligonucleotide and cloned polynucleotide enterotoxin gene probes to identify enterotoxigenic Escherichia coli.

Escherichia coli isolated from 2,126 children in Thailand and the Philippines was examined for enterotoxin production and for DNA hybridization with synthetic oligonucleotide and cloned polynucleotide enterotoxin gene probes. A total of 233 infections with E. coli that were detected by one or more of these assays were identified. Of the infections, 75% (164/233) were identified by all three met...

متن کامل

GM1 ganglioside enzyme-linked immunosorbent assay for detection of heat-labile enterotoxin produced by human and porcine Escherichia coli strains.

Human and porcine enterotoxigenic strains of Escherichia coli were cultivated in tryptone-yeast extract medium or brain heart infusion broth and tested for production of heat-labile enterotoxin by the GM1 ganglioside enzyme-linked immunosorbent assay (GM1-ELISA) and the Y1 adrenal cell assay. When testing for enterotoxigenicity by the GM1-ELISA technique, homologous antisera for human and porci...

متن کامل

Adaptation of the staphylococcal coagglutination technique for detection of heat-labile enterotoxin of Escherichia coli.

Protein A-containing staphylococci coated with specific antiserum were tested for heat-labile enterotoxin of Escherichia coli. The immunological cross-reactivity of E. coli heat-labile enterotoxin with Vibrio cholerae toxin (choleragen) was the basis for sensitizing stabilized suspensions of the Cowan I strain of Staphylococcus aureus with anticholeragen. Unconcentrated culture supernatant flui...

متن کامل

Detection of heat-labile enterotoxin-like activity in stools of patients with cholera and Escherichia coli diarrhea.

The Y1 adrenal cell tissue culture assay was used to detect heat-labile enterotoxin-like activity in the stools of 14 of 74 patients with diarrhea. A positive effect of the stool on the adrenal cells was heat-labile and neutralized by cholera antitoxin. Enterotoxin-like activity was detected in the stools of 10 of 30 patients with cholera and in those of 2 of 4 from whom heat-labile Escherichia...

متن کامل

Evaluation of a reversed passive latex agglutination test for detection of Escherichia coli heat-labile toxin in culture supernatants.

One hundred strains of Escherichia coli were tested for the production of the heat-labile enterotoxin by the Y1 adrenal cell test and a commercially available reversed passive latex agglutination test. The strains were grown in Casamino Acids-yeast extract broth, and filtered culture supernatants were tested for the presence of heat-labile enterotoxin. There was perfect correlation between the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 42 7  شماره 

صفحات  -

تاریخ انتشار 1989