Proximal humeral reconstruction using nail cement spacer in primary and metastatic tumours of proximal humerus
نویسندگان
چکیده
Limb salvage surgery for malignant tumours of proximal humerus is an operative challenge, where the surgeon has to preserve elbow and hand functions and retain shoulder stability with as much function as possible. We treated 14 consecutive patients with primary malignant or isolated metastasis of proximal humerus with surgical resection and reconstruction by nail cement spacer. There were 8 females and 6 males, with a mean age of 28.92 years (range 16-51 years) and a mean follow-up of 30.14 months (range 12-52 months). The diagnosis was osteosarcoma in 8 patients, chondrosarcoma in 4 patients and metastasis from thyroid and breast carcinoma in 1 patient each. One of our patients had radial nerve neuropraxia, 1 developed inferior subluxation and 3 developed distant metastasis. Two patients died of disease and one developed local recurrence leading to forequarter amputation, leaving a total of 11 patients with functional extremities for assessment at the time of final follow-up which was done using the Musculoskeletal Tumour Society (MSTS) score. Though we were able to preserve the elbow, wrist and hand functions in all patients, the abductor mechanism, deltoid muscle and axillary nerve were not salvageable in any of cases. The mean MSTS score at the time of final follow-up was 19.09. Thus, proximal humeral reconstruction using nail cement spacer is a technical simple, cost-effective and reproducible procedure which makes it a reliable option in subset of patients where the functions around the shoulder cannot be preserved despite costlier prosthesis.
منابع مشابه
Operative treatment of 2-part surgical neck fractures of the proximal humerus (AO 11-A3) in the elderly: Cement augmented locking plate Philos™ vs. proximal humerus nail MultiLoc®
BACKGROUND Proximal humeral fractures are with an incidence of 4-5 % the third most common fractures in the elderly. In 20 % of humeral fractures there is an indication for surgical treatment according to the modified Neer-Criteria. A secondary varus dislocation of the head fragment and cutting-out are the most common complications of angle stable locking plates in AO11-A3 fractures of the elde...
متن کاملThe Outcome of Proximal Humeral Locking Plates in the Management of Three and Four Part Proximal Humeral Fractures in Special Cohort of Young Patients in High Velocity Trauma
Background: Locking plate fixation provides satisfactory outcome following proximal humerus fractures. None of theprevious studies selectively evaluate the outcome in young patients. This study evaluates outcome of locking platesystem in the treatment of acute three- and four-part fractures in young patients.Methods: In this prospective study we included all patients who were less than 60 years...
متن کاملLong-term survival of proximal humerus allografts for reconstruction following resection of malignant bone tumours.
We previously reported early favourable results concerning allograft use in proximal humerus reconstruction following malignancy. We now present the long-term follow-up of patients who underwent tumour resection with massive humeral allograft reconstruction. This is a retrospective review of 8 consecutive patients who underwent massive proximal humeral allograft for primary or secondary bone tu...
متن کاملIntramedullary Nailing for Pathological Fractures of the Proximal Humerus
BACKGROUND Endoprosthetic reconstruction is widely applied for pathological fractures of the proximal humerus; however, functional impairment is usually unsatisfactory. The aims of the current study are to evaluate the reliability of interlocking intramedullary (IM) nailing with cement augmentation as a fixation method in proximal humeral lesions and to assess functional outcomes. METHODS We ...
متن کاملInvestigation of metallic and carbon fibre PEEK fracture fixation devices for three-part proximal humeral fractures.
A computational investigation of proximal humeral fracture fixation has been conducted. Four devices were selected for the study; a locking plate, intramedullary nail (IM Nail), K-wires and a Bilboquet device. A 3D model of a humerus was created using a process of thresholding based on the grayscale values of a CT scan of an intact humerus. An idealised three part fracture was created in additi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -
تاریخ انتشار 2013