Evaluation of coagulation stages of hemorrhaged swine: comparison of thromboelastography and rotational elastometry.
نویسندگان
چکیده
Thromboelastography (TEG) or rotational thromboelastometry (ROTEM) assesses blood viscoelastic properties and clotting kinetics that can be measured by Haemoscope TEG and Pentapharm ROTEM devices using slightly different methodologies. These devices were compared by measuring blood samples associated with various degrees of coagulopathy. Blood samples, collected from swine undergoing three types of severe injury and resuscitation protocol resulting in normal, hypercoagulopathy, and hypocoagulopathy, were assessed with TEG or ROTEM before the surgical procedures, and after injury, fluid resuscitation, and simulated hospital phase. Standard clotting parameters were compared by Student's t-test at a significance of a P value less than 0.05. Regression analysis indicated a positive correlation between TEG and ROTEM for reaction time (R), clotting rate (K), and maximum amplitude (Ma) parameters. With samples of normal coagulation, R (440 +/- 136 vs. 391 +/- 73 s), K (99 +/- 39 vs. 81 +/- 20 s), and Ma (74 +/- 4 vs. 69 +/- 5 mm) were higher, whereas (alpha) (68 +/- 8 vs. 75 +/- 3 mm) was lower with TEG than ROTEM, respectively; a P value is less than 0.05. The magnitude of changes from baseline in hypercoagulable or hypocoagulable samples due to level of injury was equivalent with TEG and ROTEM indicating comparable use of the instruments. However, when samples were extremely hypocoagulopathic due to resuscitation fluid, the TEG values could not be readily determined. Overall, TEG readings were higher than ROTEM readings; this disparity between the two instruments was attenuated with hypercoaguable samples. Both devices yielded similar information regarding the status of coagulation related to trauma. Because of operating characteristics, the same instrument should be used for monitoring the same patient or study.
منابع مشابه
Author’s response to reviews Title: Assessment of Haemostasis in Patients undergoing Emergent Neurosurgery by Rotational Elastometry and Standard Coagulation Tests: A Prospective Observational Study Authors: Christoph Ellenberger ([email protected])
Title: Assessment of Haemostasis in Patients undergoing Emergent Neurosurgery by Rotational Elastometry and Standard Coagulation Tests: A Prospective Observational Study Authors: Christoph Ellenberger ([email protected]) Najia Garofano ([email protected]) John Diaper ([email protected]) Gleicy Barcelos ([email protected]) Gordana Pavlovic (Gordana.Pavlovic@hc...
متن کاملPerformance Evaluation of the Coagulation and Flocculation Process in Removing Pollutants from textile Dyeing Factory Wastewater
Background and Objective: In this research, the performance of coagulation and flocculation process for the removal of pollutants from raw wastewater as well as anaerobic unit effluent of biological treatment of textile dyeing factory wastewater treatment plant was investigated. Methods: For this purpose, the Jar test unit as a batch reactor, FeCl3, PAC, and Alum as coagulants, and two polyelec...
متن کاملAn in vitro evaluation of standard rotational thromboelastography in monitoring of effects of recombinant factor VIIa on coagulopathy induced by hydroxy ethyl starch
BACKGROUND: Rotational thromboelastography (ROTEG) has been proposed as a monitoring tool that can be used to monitor treatment of hemophilia with recombinant factor VIIa (rFVIIa). In these studies special non-standard reagents were used as activators of the coagulation. The aim of this study was to evaluate if standard ROTEG analysis could be used for monitoring of effects of recombinant facto...
متن کاملThe effects of hypothermia on fibrinogen metabolism and coagulation function in swine.
Clinical coagulopathy frequently occurs in the presence of hypothermia. The primary purpose of this study was to investigate the effects of hypothermia on clotting protein fibrinogen metabolism and on coagulation function in a swine model. Twelve pigs were randomly allocated into control and hypothermia groups. Hypothermia of 32 degrees C was induced using a blanket with circulating water at 4 ...
متن کاملAssessment of Haemostasis in patients undergoing emergent neurosurgery by rotational Elastometry and standard coagulation tests: a prospective observational study
BACKGROUND Rotational elastometry (ROTEM) has been shown useful to monitor coagulation in trauma patients and in major elective surgery. In this study, we aimed to evaluate the utility of ROTEM to identify hemostatic disturbances and to predict the need for transfusion, compared with standard coagulation tests (SCTs) in patients undergoing emergent neurosurgery. METHODS Over a four-year perio...