Comparison of keratometry and videokeratography after penetrating keratoplasty.

نویسندگان

  • C H Karabatsas
  • S D Cook
  • K Powell
  • J M Sparrow
چکیده

BACKGROUND As new methods for corneal curvature measurement have evolved, users of videokeratscopes need to know the practical limitations of these instruments. We assessed agreement between keratometry and videokeratography in measuring highly astigmatic corneas. METHODS Two independent examiners made three keratometric and videokeratographic measurements on each of 33 corneas after penetrating keratoplasty. The non-orthogonal keratometric readings obtained with a Zeiss 10 SL/O keratometer (Carl Zeiss Ltd.) were compared to the non-orthogonal simK readings (maxK, minK) calculated by the algorithms of a TMS-1 videokeratoscope (Tomey). Measurement agreement was evaluated for steep and flat meridian power and location, and astigmatism magnitude (D). RESULTS A systematic bias of the TMS-1 in measuring steeper than keratometry for the steep meridian was demonstrated (95% confidence interval: -0.34 to -1.20 D). The limits of agreement (d - 2SD to d + 2SD) between the two instruments were found to be unacceptable for clinical purposes in measuring steep meridian power (-3.17 to +1.63 D), flat meridian power (-4.92 to +4.48 D) and astigmatism magnitude (-5.84 to +4.87 D). Clinically acceptable differences were observed in identification of steep and flat meridian location. CONCLUSIONS The Zeiss 10 SL/O keratometer and the TMS-1 videokeratoscope showed poor measurement agreement for irregular corneal surfaces, despite the good correlation previously shown between keratometry and videokeratography in calibrated spheres and regular corneas. The TMS-1 showed a systematic bias, measuring a greater power in the steeper meridian than the Zeiss 10 SL/O keratometer. It is suggested that the two instruments cannot be used interchangeably in comparing the curvature of corneas after penetrating keratoplasty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Conductive keratoplasty to treat complications of LASIK and photorefractive keratectomy.

PURPOSE To assess the outcomes of conductive keratoplasty (CK) for patients with complications related to LASIK or photorefractive keratectomy (PRK). DESIGN Retrospective, noncomparative, interventional case series. PARTICIPANTS Sixteen eyes of 15 patients were treated using CK after complications of initial LASIK or PRK surgeries. Five cases are described in detail. INTERVENTION Rehabili...

متن کامل

Effect of disagreement between refractive, keratometric, and topographic determination of astigmatic axis on suture removal after penetrating keratoplasty.

BACKGROUND/AIMS Post-keratoplasty astigmatism can be managed by selective suture removal in the steep axis. Corneal topography, keratometry, and refraction are used to determine the steep axis for suture removal. However, often there is a disagreement between the topographically determined steep axis and sutures to be removed and that determined by keratometry and refraction. The purpose of thi...

متن کامل

Surgical treatment of advanced pellucid marginal degeneration.

PURPOSE To determine the efficacy of simultaneous peripheral crescentic lamellar keratoplasty (LK) and central penetrating keratoplasty (PK) for advanced pellucid marginal degeneration (PMD). DESIGN Retrospective, noncomparative, interventional case series. PARTICIPANTS Five patients with advanced PMD. METHOD Simultaneous peripheral crescentic LK and central PK followed by selective sutur...

متن کامل

Intraocular lens power calculation for cataract surgery after photorefractive keratectomy.

OBJECTIVE To assess intraocular lens (IOL) power calculations in patients undergoing cataract surgery after excimer laser photorefractive keratectomy (PRK) for myopia. METHODS Four eyes of two patients underwent phacoemulsification with IOL implantation after PRK for myopia. The estimated refractive error that would have been induced had the IOL predicted for emmetropia been implanted was cal...

متن کامل

Myopia following penetrating keratoplasty for keratoconus.

The frequent occurrence of spherical myopia after penetrating keratoplasty for keratoconus is partly the result of the excessive dioptric power of the grafted cornea which occurs when the diameter selected for the donor button is greater than the diameter of the host incision. This excessive power could be reduced by eliminating disparity between the diameters of the graft and host. To determin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 14 4  شماره 

صفحات  -

تاریخ انتشار 1998