Sacroiliac Joint Arthrodesis-MIS Technique with Titanium Implants: Report of the First 50 Patients and Outcomes
نویسنده
چکیده
This retrospective study of 50 consecutive patients treated by a single orthopedic spine surgeon in private practice was conducted to evaluate the safety and efficacy of minimally invasive sacroiliac joint fusion using a series of triangular, porous plasma spray coated titanium implants.Medical charts were reviewed for perioperative metrics, complications, pain, quality of life and satisfaction with surgery. All patients were contacted at a 24 months post-op to assess SI joint pain, satisfaction with surgery and work status.An early and sustained statistically significant improvement in pain function was identified at all post-operative time points (ANOVA, p<0.000). A clinically significant improvement (>2 point change from baseline) was observed in 7 out of 9 domains of daily living. The complication rate was low and more than 80% of patients would have the same surgery again.MIS SI joint fusion appears to be a safe and effective procedure for the treatment of sacroiliac joint disruption or degenerative sacroiliitis.
منابع مشابه
One year successful outcomes for novel sacroiliac joint arthrodesis system
UNLABELLED BACKGROUND SI joint pain can mimic discogenic low back pain or even radicular pain. Patient presentations vary considerably and conditions may include low back, groin, and/or radicular pain, leading to the potential for inaccurate diagnosis and treatment. Despite the large number of patients with SI joint pain, treatment options have been limited to conservative care involving phy...
متن کاملFive-Year Clinical and Radiographic Outcomes After Minimally Invasive Sacroiliac Joint Fusion Using Triangular Implants
OBJECT Previous reports of minimally invasive (MIS) sacroiliac (SI) joint fusion for low back, SI joint, and buttock pain secondary to SI joint disorders have shown favorable short- and mid-term outcomes. Herein we present 5-year clinical and radiographic outcomes after MIS SI joint fusion using a series of triangular porous titanium plasma spray (TPS) coated implants. METHODS Consecutive pat...
متن کاملOne-year outcomes after minimally invasive sacroiliac joint fusion with a series of triangular implants: a multicenter, patient-level analysis
BACKGROUND Sacroiliac joint (SI) pain is an often-overlooked cause of lower-back pain, due in part to a lack of specific findings on radiographs and a symptom profile similar to other back-related disorders. A minimally invasive surgical (MIS) approach to SI joint fusion using a series of triangular, titanium plasma spray-coated implants has shown favorable outcomes in patients with SI joint pa...
متن کاملOpen versus minimally invasive sacroiliac joint fusion: a multi-center comparison of perioperative measures and clinical outcomes
BACKGROUND Sacroiliac (SI) joint pain is an under diagnosed source of low back pain due in part to lack of visible pathology on radiographs and symptoms mimicking other back-related disorders. Open SI joint fusion has been performed since the 1920s. This technique has fallen out of favor with the introduction of minimally invasive options. To date there has been no direct comparison between ope...
متن کاملMinimally Invasive Sacroiliac Joint Fusion: One-Year Outcomes in 40 Patients
Background. SI joint pain is difficult to diagnose due to overlapping symptoms of the lumbar spine, and until recently, treatment options have been limited. The purpose of this retrospective study is to report on the safety and effectiveness of MIS SI joint arthrodesis using a series of triangular, porous plasma coated implants in patients refractory to conservative care. Methods. We report on ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 6 شماره
صفحات -