Comparison of Kinematics and Tibiofemoral Contact Pressures for Native and Transplanted Lateral Menisci

نویسندگان

  • Patrick C. McCulloch
  • Donald Dolce
  • Hugh L. Jones
  • Andrea Gale
  • Michael G. Hogen
  • Jason Alder
  • Jeremiah E. Palmer
  • Philip C. Noble
چکیده

BACKGROUND Lateral meniscus transplantation is a proven treatment option for the meniscus-deficient knee, yet little is known about meniscal kinematics, strain, and tibiofemoral contact pressure changes after transplantation or the effect of altered root position in lateral meniscus transplantation. PURPOSE To compare the native lateral meniscal kinematics, strain, and tibiofemoral contact pressures to a best-case scenario meniscus transplant with perfectly matched size and position and to determine how sensitive these factors are to subtle changes in shape and position by using a nonanatomic meniscus transplant position. STUDY DESIGN Controlled laboratory study. METHODS The lateral menisci of 8 cadaveric knees were circumferentially implanted with radiopaque spherical markers. They were mounted to a testing apparatus applying muscle and ground-reaction forces. The meniscus was evaluated at 0°, 30°, 90°, and 115° of knee flexion using Roentgen stereophotogrammetric analysis (RSA), with a pressure sensor affixed to the lateral tibial plateau. Measurements were recorded for 3 states: the native lateral meniscus, an anatomic autograft transplant, and a nonanatomic autograft transplant with an anteriorized posterior root position. RESULTS After transplantation, there was less posterior displacement in both the anatomic and nonanatomic transplant states compared with the native meniscus, but this was not significant. The largest lateral translation in the native state was 2.38 ± 1.58 mm at the anterolateral region from 0° to 90°, which was increased to 3.28 ± 1.39 mm (P = .25) and 3.12 ± 1.18 mm (P = .30) in the anatomic and nonanatomic transplant states, respectively. Internal deformations of the transplant states were more constrained, suggesting less compliance. The native meniscus distributed load over 223 mm2, while both the anatomic (160 mm2) and nonanatomic (102 mm2) states concentrated pressure anteriorly to the tibial plateau centroid. CONCLUSION This study is the first to characterize kinematics in the native lateral meniscus compared with a transplanted state utilizing RSA. Results demonstrate increased meniscal constraint and pressure concentrations even after an ideal size and position matched transplantation, which further increased with a nonanatomic posterior root position. CLINICAL RELEVANCE The results show that kinematics are similar in both transplanted states when compared with the native meniscus at various flexion angles. Because both transplanted states were more constrained with less deformation compared with the native state, this should allow for relatively safe postoperative range of motion. However, in the transplanted states, peak pressures were distributed over a smaller area and shifted anteriorly. This pattern was exacerbated in the nonanatomic state compared with anatomic. This could have detrimental effects with regard to articular cartilage degeneration, and ultimately result in a failed transplantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The sensitivity of tibiofemoral contact pressure to the size and shape of the lateral and medial menisci.

In an effort to prevent degeneration of articular cartilage associated with meniscectomies, both meniscal allografts and synthetic replacements have been studied. A number of biomechanical criteria may be important for a meniscal replacement to restore normal tibiofemoral contact pressure in the knee joint and hence be clinically successful. One of these criteria is geometric similarity. The ob...

متن کامل

Biomechanics of Hyperflexion and Kneeling before and after Total Knee Arthroplasty

The capacity to perform certain activities is frequently compromised after total knee arthroplasty (TKA) due to a functional decline resulting from decreased range of motion and a diminished ability to kneel. In this manuscript, the current biomechanical understanding of hyperflexion and kneeling before and after TKA will be discussed. Patellofemoral and tibiofemoral joint contact area, contact...

متن کامل

Subject-specific knee joint geometry improves predictions of medial tibiofemoral contact forces.

Estimating tibiofemoral joint contact forces is important for understanding the initiation and progression of knee osteoarthritis. However, tibiofemoral contact force predictions are influenced by many factors including muscle forces and anatomical representations of the knee joint. This study aimed to investigate the influence of subject-specific geometry and knee joint kinematics on the predi...

متن کامل

In vivo Kinematics of the Knee after a Posterior Cruciate-Substituting Total Knee Arthroplasty: A Comparison between Caucasian and South Korean Patients

PURPOSE This study compared in vivo kinematic differences between Caucasian and South Korean patients after a posterior-substituting total knee arthroplasty (PS-TKA). MATERIALS AND METHODS In vivo motions of 9 Caucasian and 13 South Korean knees with a PS-TKA during weight bearing single leg lunge were determined using a dual fluoroscopic imaging technique. Normalized tibiofemoral condylar mo...

متن کامل

Jaaos-d-14-00003 71..76

Posterior root avulsions of the medial and lateral menisci result in decreased areas of tibiofemoral contact and increased tibiofemoral contact pressures. These avulsions may lead to the development of osteoarthritis. Therefore, two surgical techniques, the transtibial pullout repairand thesutureanchor repair, have recentlybeendeveloped to restore the native structure and function of the menisc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016