Investigation of the potential utility of single-bounce attenuated total reflectance Fourier transform infrared spectroscopy in the analysis of distilled liquors and wines.

نویسندگان

  • Robert A Cocciardi
  • Ashraf A Ismail
  • Jacqueline Sedman
چکیده

A new Fourier transform infrared (FTIR) spectroscopic method based on single-bounce attenuated total reflectance (SB-ATR) spectroscopy was developed for the analysis of distilled liquors and wines. For distilled liquors, a partial least-squares (PLS) calibration was developed for alcohol determination based on the SB-ATR/FTIR spectra of mixtures of ethanol and distilled water. An independent set of 12 different distilled liquor samples was predicted from the PLS calibration, and a standard deviation of the differences for accuracy (SDD(a)) between actual and predicted values of 0.142% (v/v) was obtained. The potential utility of SB-ATR/FTIR spectroscopy for the analysis of wines was initially evaluated based on a comparison with Fourier transform near-infrared (FT-NIR) spectroscopy and FTIR spectroscopy using a flow-through transmission cell. PLS calibrations for alcohol, total reducing sugars, total acidity and pH were developed using pre-analyzed wine samples (n = 28), and for SB-ATR/FTIR spectroscopy, the SDD(a) for the leave-one-out cross-validation statistics were of the order of 0.100% (v/v), 0.707 g L(-1), 0.189 g L(-1) (H2SO4), and 0.230, respectively. Overall, the SB-ATR/FTIR results were better than those obtained using FT-NIR spectroscopy and comparable to those obtained with transmission FTIR spectroscopy. A PLS calibration based on preanalyzed wine samples (n = 72) for the prediction of 11 different components and parameters in wines by SB-ATR/FTIR spectroscopy was subsequently developed and validated using an independent sample set (n = 77). Good coefficients of correlation between the reference and predicted values for the validation set were obtained for most of the components and parameters except citric acid, volatile acids, and total SO2. The results of this study demonstrate the suitability of SB-ATR/FTIR spectroscopy for the routine analysis of distilled liquors and wines.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fabrication of Polyvinyl Alcohol/Kefiran Nanofibers Membrane Using Electrospinning

The Poly (vinyl alcohol)/Kefirane nanofiber membrane was successfully fabricated for the firsttime using electrospinning of the polyvinyl alcohol (PVA) and Kefirane blend solution. Scanningelectron microscope (SEM), attenuated total reflectance Fourier transform infrared (ATRFT-IR), and differential scanning calorimetry (DSC) were used to characterize the electrospunPoly (vinyl alcohol)/Kefiran...

متن کامل

Single Base Extension and Fourier-Transform Infra-Red Spectroscopy Techniques; Further Approaches in Discriminating Hazelnut-Adulterated Olive Oil

  Background:Confirmation of olive oil authenticity and particularly virgin olive oil has a great importance. Several advanced chemical and genetic analyses have been used to monitor especial components; however each has its limitations especially when detecting hazelnut-adulterated olive oil. Objectives:The objective of this research is to assess the presence of trace amoun...

متن کامل

Economical Appraisal of Total Aflatoxin Level in the Poultry Feeds by Fourier Transform Infrared Spectroscopy

Single-bounce attenuated total reflectance (SB-ATR) Fourier transform infrared (FTIR) spectroscopy has been used for the quantitative determination of total aflatoxins in the broiler poultry feed. An FTIR calibration spanning the range 1-70 μg/L aflatoxin standards in (70:30, v/v) methanol-water solvent system based on partial least square (PLS) model, developed by relating mid IR region betwee...

متن کامل

Fabrication of MgF2-SiO2 Nanocomposite Thin Films and Investigation of Their Optical and Hydrophobic Properties

In this research, MgF2-2%SiO2/MgF2 thin films were applied on a glass substrate. At first, MgF2 thin films with the optical thickness were deposited on the glass slide substrates. Then, MgF2-2%SiO2 thin films were deposited on the glass coated with MgF2 thin films. Finally, the nanocomposite thin films were surface treated by the PFTS solution. Characterization of the thin film was done by X-Ra...

متن کامل

Real-Time Attenuated Total Reflectance-Fourier Transform Infrared Spectroscopy To Monitor Multiacrylate Polymerization Reactions

Real-time attenuated total reflectance-Fourier transform infrared spectroscopy was used to follow the conversion during acrylate polymerizations by measuring the presence of functional groups a t finite depths from the crystal surface. By varying the film thickness, the reactivity of multiacrylates could be spatially resolved. These results were compared to results from differential photocalori...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of agricultural and food chemistry

دوره 53 8  شماره 

صفحات  -

تاریخ انتشار 2005