A Subband-Specific Deconvolution Model for MTF Improvement in CT

نویسندگان

  • Seokmin Han
  • Kihwan Choi
  • Sang Wook Yoo
چکیده

The purpose of this research is to achieve uniform spatial resolution in CT (computed tomography) images without hardware modification. The main idea of this study is to consider geometry optics model, which can provide the approximate blurring PSF (point spread function) kernel, which varies according to the distance from X-ray tube to each pixel. The FOV (field of view) was divided into several band regions based on the distance from X-ray source, and each region was deconvolved with different deconvolution kernels. Though more precise calculation for the PSF for deconvolution is possible as the number of subbands increases, we set the number of subbands to 11. 11 subband settings seem to be a balancing point to reduce noise boost, while MTF (modulation transfer function) increase still remains. As the results show, subband-wise deconvolution makes image resolution (in terms of MTF) relatively uniform across the FOV. The results show that spatial resolution in CT images can be uniform across the FOV without using additional equipment. The beauty of this method is that it can be applied to any CT system as long as we know the specific system parameters and determine the appropriate PSF for deconvolution maps of the system. The proposed algorithm shows promising result in improving spatial resolution uniformity while avoiding the excessive noise boost.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Fabrication Process of MTF Phantom CT Scan

Introduction: One of the main steps in the optimization process in diagnostic imaging is the quality control of radiology devices. The usual method of CT scan calibration is used of a phantom. The phantom created a certain weakening for the radiation through which it passes. One of the most suitable methods for quantitative analysis of the resolution and contrast in CT scan im...

متن کامل

Subband temporal modulation spectrum normalization for automatic speech recognition in reverberant environments

Speech recognition in reverberant environments is still a challenge problem. In this paper, we first investigated the reverberation effect on subband temporal envelopes by using the modulation transfer function (MTF). Based on the investigation, we proposed an algorithm which normalizes the subband temporal modulation spectrum (TMS) to reduce the diffusion effect of the reverberation. During th...

متن کامل

A fast iterative thresholding algorithm for wavelet-regularized deconvolution

We present an iterative deconvolution algorithm that minimizes a functional with a non-quadratic waveletdomain regularization term. Our approach is to introduce subband-dependent parameters into the bound optimization framework of Daubechies et al.; it is sufficiently general to cover arbitrary choices of wavelet bases (non-orthonormal or redundant). The resulting procedure alternates between t...

متن کامل

Dual Tree Complex Wavelet based Regularized Deconvolution for Medical Images

Deblurring in the presence of noise is a hard problem, especially in Ultrasound and CT images. In this paper, we propose a hybrid approach of wavelet-based image deconvolution that incorporates Fourier-domain system inversion followed by wavelet-domain noise suppression. In contrast to conventional wavelet-based deconvolution methods, the algorithm employs a regularized inverse filter to operat...

متن کامل

Experimental Measurement of Modulation Transfer Function (MTF) in Five Commercial CT Scanners

The modulation transfer function (MTF) is the technical description of spatial resolution for most imaging systems. the MTF describes how well an imaging system processes signal [1,4]. There are several methods for calculation of MTF that can be categorized in theoretical and experimental methods. In this study, in order to compare the performance of five different commercial CT scanner, an exp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2017  شماره 

صفحات  -

تاریخ انتشار 2017