PURPOSE The primary objective was to compare measures of bulbar redness objectively using a photometric method with standard grading methods. Measures of redness were made on 24 participants wearing a silicone hydrogel contact lens in one eye for overnight wear. This report compares hyperaemia after 1 week of daily wear (baseline) with redness measured after 6 months of overnight wear. METHOD A new method of objectively measuring bulbar conjunctival redness was performed using the Spectrascan650 Photometer by Photo Research under fixed illumination. Photometric measures in CIEu(*) chromaticity values involve the measurement of chromaticity, a physical analogue of redness, greenness and blueness in the image. This method was validated in Part 1 of the study using repeated measurements on the photographic CCLRU scale. In Part 2 of the study, the photographic grading scale (CCLRU) from 0 (none) to 100 (extreme) was used to make the comparison. RESULTS Part 1 indicated that the photometer provides a repeatable and reliable measure of bulbar redness (CCC=0.989). A moderately strong and significant correlation was found between the CIEu(*) chromaticity values and the analogue data (R=0.795, p=0.000) at each measurement session (from baseline to 1 day, 1 week, and 1, 3 and 6 months of overnight wear). CONCLUSIONS This new standardized and objective method of measuring bulbar redness has great potential to replace subjective grading scales, especially with multi-centre studies, where variability between investigators occurs. This method may also detect smaller changes between visits or between eyes.
منابع مشابه
The Ocular Redness Index: a novel automated method for measuring ocular injection.
PURPOSE To develop and validate a novel automated system to assess ocular redness (OR) in clinical images. METHODS We developed a novel software that quantifies OR in digital images based on a mathematic algorithm using a centesimal continuous scoring scale. Subsequently, we conducted a study to validate the scores obtained with this system by correlating them with those obtained by two physi...
متن کاملThe use of fractal analysis and photometry to estimate the accuracy of bulbar redness grading scales.
PURPOSE To use physical attributes of redness to determine the accuracy of four bulbar redness grading scales, and to cross-calibrate the scales based on these physical measures. METHODS Two image-processing metrics, fractal dimension (D) and percentage of pixel coverage (% PC), as well as photometric chromaticity were selected as physical measures, to describe and compare grades of bulbar re...
متن کاملLimbal and bulbar hyperaemia in normal eyes.
PURPOSE To investigate the appearance of limbal and bulbar hyperaemia in normal eyes, their relationship and the inter-observer agreement of clinical grading. METHODS The right eyes of 120 healthy, non-contact lens-wearing subjects (m = 57, f = 63, median age = 45 years, range 18-77 years) were examined by two trained observers. Limbal and bulbar hyperaemia were scored using the Cornea and Co...
متن کاملIncremental nature of anterior eye grading scales determined by objective image analysis.
AIM To use previously validated image analysis techniques to determine the incremental nature of printed subjective anterior eye grading scales. METHODS A purpose designed computer program was written to detect edges using a 3 x 3 kernal and to extract colour planes in the selected area of an image. Annunziato and Efron pictorial, and CCLRU and Vistakon-Synoptik photographic grades of bulbar ...