Dosimetric and radiobiological impact of intensity modulated proton therapy and RapidArc planning for high‐risk prostate cancer with seminal vesicles
نویسندگان
چکیده
INTRODUCTION The purpose of this study was to evaluate the dosimetric and radiobiological impact of intensity modulated proton therapy (IMPT) and RapidArc planning for high-risk prostate cancer with seminal vesicles. METHODS Ten high-risk prostate cancer cases were included in this retrospective study. For each case, IMPT plans were generated using multiple field optimisation (MFO) technique (two fields) with XiO treatment planning system (TPS), whereas RapidArc plans were generated using double-arc technique (two full arcs) with Eclipse TPS. IMPT and RapidArc plans were optimised for a total prescription dose of 79.2 Gy (relative biological effectiveness (RBE)) and 79.2 Gy, respectively, using identical dose-volume constraints. IMPT and RapidArc plans were then normalised such that at least 95% of the planning target volume (PTV) received the prescription dose. RESULTS The mean and maximum PTV doses were comparable in IMPT plans (80.1 ± 0.3 Gy (RBE) and 82.6 ± 1.0 Gy (RBE) respectively) and RapidArc plans (80.3 ± 0.3 Gy and 82.8 ± 0.6 Gy respectively) with P = 0.088 and P = 0.499 respectively. The mean doses of the rectum and bladder were found to be significantly lower in IMPT plans (16.9 ± 5.8 Gy (RBE) and 17.5 ± 5.4 Gy (RBE) respectively) when compared to RapidArc plans (41.9 ± 5.7 Gy and 32.5 ± 7.8 Gy respectively) with P < 0.000 and P < 0.000 respectively. For the rectum, IMPT produced lower V30 (21.0 ± 9.6% vs. 68.5 ± 10.0%; P < 0.000), V50 (14.3 ± 5.8% vs. 45.0 ± 10.0%; P < 0.000) and V70 (6.9 ± 3.4% vs. 12.8 ± 3.6%; P < 0.000) compared to RapidArc. For the bladder, IMPT produced lower V30 (23.2 ± 7.0% vs. 50.9 ± 15.6%; P < 0.000) and V50 (16.6 ± 5.4% vs. 25.1 ± 9.6%; P = 0.001), but similar V70 (9.7 ± 3.5% vs. 10.5 ± 4.2%; P = 0.111) compared to RapidArc. RapidArc produced lower mean dose for both the right femoral head (19.5 ± 4.2 Gy vs. 27.4 ± 4.5 Gy (RBE); P < 0.000) and left femoral head (18.0 ± 4.3 Gy vs. 28.0 ± 5.6 Gy (RBE); P < 0.000). Both IMPT and RapidArc produced comparable bladder normal tissue complication probability (NTCP) (0.6 ± 0.2% vs. 0.5 ± 0.2%; P = 0.152). The rectal NTCP was found to be lower using IMPT (0.8 ± 0.7%) than using RapidArc (1.7 ± 0.7%) with P < 0.000. CONCLUSION Both IMPT and RapidArc techniques provided comparable mean and maximum PTV doses. For the rectum, IMPT produced better dosimetric results in the low-, medium- and high-dose regions and lower NTCP compared to RapidArc. For the bladder, the NTCP and dosimetric results in the high-dose region were comparable in both sets of plans, whereas IMPT produced better dosimetric results in the low- and medium-dose regions.
منابع مشابه
Comparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy
Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...
متن کامل3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis
Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...
متن کاملComparison of dosimetric and radiobiological effects of various IMRT techniques regarding to joint volume between target tissue and organs at risk in prostate cancer patients
Background: Intensity-modulated radiotherapy (IMRT) is one of the most usable methods in prostate radiotherapy that is used with different techniques. The aim of this study was to evaluate and compare the dosimetric and radiobiological effects of prostate IMRT techniques regarding to joint volume between the target tissue and organs at risk as a patients anatomical parameter. Methods: This res...
متن کاملDosimetric Comparison and Evaluation of 4 Stereotactic Body Radiotherapy Techniques for the Treatment of Prostate Cancer
PURPOSE The aim of this study was to compare dosimetric characteristics, monitor unit, and delivery efficiency of 4 different stereotactic body radiotherapy techniques for the treatment of prostate cancer. METHODS This study included 8 patients with localized prostate cancer. Dosimetric assets of 4 delivery techniques for stereotactic body radiotherapy were evaluated: robotic CyberKnife, nonc...
متن کاملSimultaneous integrated boost plan comparison of volumetric‐modulated arc therapy and sliding window intensity‐modulated radiotherapy for whole pelvis irradiation of locally advanced prostate cancer
Concurrent radiotherapy to the pelvis plus a prostate boost with long-term androgen deprivation is a standard of care for locally advanced prostate cancer. IMRT has the ability to deliver highly conformal dose to the target while lowering irradiation of critical organs around the prostate. Volumetric-modulated arc therapy is able to reduce treatment time, but its impact on organ sparing is stil...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 64 شماره
صفحات -
تاریخ انتشار 2017