Combined MR imaging and numerical simulation of flow in realistic arterial bypass graft models.
نویسندگان
چکیده
We report methods for (a) transforming a three-dimensional geometry acquired by magnetic resonance angiography (MRA) in vivo, or by imaging a model cast, into a computational surface representation, (b) use of this to construct a three dimensional numerical grid for computational fluid dynamic (CFD) studies, and (c) use of the surface representation to produce a stereo-lithographic replica of the real detailed geometry, at a scale convenient for detailed magnetic resonance imaging (MRI) flow studies. This is applied to assess the local flow field in realistic geometry arterial bypass grafts. Results from a parallel numerical simulation and MRI measurement of flow in an aorto-coronary bypass graft with various inlet flow conditions demonstrate the strong influence of the graft inlet waveform on the perianastomotic flow field. A sinusoidal and a multi harmonic coronary flow waveform both with a mean Reynolds number (Re) of 100 and a Womersley parameter of 2.7 were applied at the graft inlet. A weak axial flow separation region just distal to the toe was found in sinusoidal flow near end deceleration (Re = 25). At the same location and approximately the same point in the cycle (Re = 30) but in coronary flow, the axial flow separation was stronger and more spatially pronounced. No axial flow separation occurred in steady flow for Re = 100. Numerical predictions indicate a region in the vicinity of the suture line (where there is a local narrowing of the graft) with a wall shear magnitude in excess of five times that associated with fully developed flow at the graft inlet.
منابع مشابه
Numerical Study of Hemodynamic Wall Parameters on Pulsatile Flow through Arterial Stenosis
In this paper hemodynamic wall parameters which play an important role to diagnose arterial disease were studied and compared for three different rheology models (Newtonian, Power law and Quemada). Also because of the pulsatile behavior of blood flow the results were obtained for three Womersley numbers which represent the frequencies of the applied pulses. Results show that Quemada model alway...
متن کاملMean arterial pressure required for maintaining patency of extracranial-to-intracranial bypass grafts: an investigation with computational hemodynamic models-case series.
BACKGROUND Maintaining flow in a newly established high-flow bypass into the intracranial circulation may be threatened by low blood pressure. OBJECTIVE To identify mean arterial blood pressure below which early graft failure may ensue. METHODS Computational fluid dynamic blood flow simulation and Doppler ultrasound-derived velocities were combined to study 12 patients with common carotid-t...
متن کاملNumerical Investigation of Angulation Effects in Stenosed Renal Arteries
Background: Numerical study of angulation effects of renal arteries on blood flow has been of great interest for many researchers.Objective: This paper aims at numerically determining the angulation effects of stenosed renal arteries on blood flow velocity and renal mass flow.Method: An anatomically realistic model of abdominal aorta and renal arteries is reconstructed from CT-scan images and u...
متن کاملمقایسه دی اکسیدکربن انتهای بازدمی و شریانی در بیماران کاندید پیوند عروق کرونر
Background: Measuring end tidal carbon dioxide (ETCo2) is one of the methods used for estimating arterial carbon dioxide (PaCo2) during general anesthesia. ETCo2 measurements maybe obviate the need for repeating arterial puncture for determination of arterial PaCo2. This study performed to determine the accuracy of ETCo2 levels as a measure of PaCo2 levels in patients undergoing coronary artery...
متن کاملEffect of Breath Holding on Blood Flow Measurement using Fast Velocity Encoded Cine MR Imaging
Introduction Velocity encoded tine (VEC) MR imaging provides quantitative assessment of blood flow in the cardiovascular system. With use of segmented k-space fast VEC MR imaging, noninvasive assessment of blood flow and vasodilator flow reserve in the coronary artery and coronary arterial bypass graft can be obtained within a single breath-hold time. However, it has been pointed out that blood...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biorheology
دوره 39 3-4 شماره
صفحات -
تاریخ انتشار 2002