Electrochemical behaviour of cytochrome c at electrically heated microelectrodes.
نویسندگان
چکیده
The structural changes in cytochrome c with temperature have been been followed using a recently developed electrically-heated microelectrode sensor. Differential pulse voltammetry was used to perform electrochemical measurements of cytochrome c oxidation at different temperatures at heated bare gold electrodes contained in phosphate-buffered cytochrome c solution at room temperature. The voltammetric response shows the onset of unfolding and a marked dependence of the signal on electrode temperature. This augurs well for applications of heated electrodes as local probes in the study of the temperature dependence of electron transfer processes of other redox proteins, avoiding problems of bulk deterioration.
منابع مشابه
Voltammetric Detection of Antioxidative Properties of Flavonoids Using Electrically Heated DNA Modified Carbon Paste Electrode
A simple electrochemical sensor consisting of electrically heated carbon paste electrode with the surface modified by dsDNA is used to characterize voltammetric behaviour and antioxidative activity of four selected flavonoids. Quercetin, rutin, catechin and epigallocatechin gallate accumulate within the DNA layer. A positive effect of the electrode temperature within the range of 20 to 38 oC on...
متن کاملELECTROCHEMICAL BEHAVIOUR OF U(V1) NITRATE IN CHLOROFORM AT A MERCURY ELECTRODE THE DEPENDENCE ON SUPPORTING ELECTROLYTE
The mechanistic aspects of the electrochemical reduction of U(V1) nitrate at a mercury electrode in chloroform, using three different supporting electrolytes, are described. In the presence of tetrabutylarnmonium perchlorate (TBAP) as a neutral electrolyte, UO (NO ) , reduced in two irreversible electrochemical steps to form a U(V1)-U(V) binuclear complex and U(IV), respectively. In the pr...
متن کاملIntegration of thermocouple microelectrode in the scanning electrochemical microscope at variable temperatures: simultaneous temperature and electrochemical imaging and its kinetic studies
We describe herein a method for the simultaneous measurement of temperature and electrochemical signal with a new type of thermocouple microelectrode. The thermocouple microelectrode can be used not only as a thermometer but also as a scanning electrochemical microscope (SECM) tip in the reaction between tip-generated bromine and a heated Cu sample. The influence of temperature on the SECM imag...
متن کاملA competitive electrochemical immunosensor for the detection of human interleukin-6 based on the electrically heated carbon electrode and silver nanoparticles functionalized labels.
A facile one-step electrochemical reduction method was developed to prepare electrochemically reduced graphene oxide (ERGO) and gold-palladium bimetallic nanoparticles (AuPdNPs) as the platform of immunosensor. A novel competitive electrochemical immunosensor was then proposed by combining the ERGO-AuPdNPs platform with silver nanoparticles (AgNPs) functionalized polystyrene bionanolabel for th...
متن کاملCarbon Fiber-based Microelectrodes and Microbiosensors
The chemically relatively inert carbon fiber (CF) has outstanding mechanical and electrical properties and provides an excellent base electrode for electrophysiological, electrochemical and biosensor applications on a micrometer or perhaps even on a submicrometer scale. CF microelectrodes have been used to record neuronal action potentials (spikes) since 1979 (Armstrong-James & Millar, 1979). T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of pharmaceutical and biomedical analysis
دوره 19 1-2 شماره
صفحات -
تاریخ انتشار 1999