Comparison of the Levitan FPS Scope and the single-use bougie for simulated difficult intubation in anaesthetised patients.

نویسندگان

  • K B Greenland
  • G Liu
  • H Tan
  • M Edwards
  • M G Irwin
چکیده

A randomised cross-over study was performed in 34 patients with no evidence of airway difficulties, following induction of general anaesthesia, to compare the efficacy of the Levitan FPS scope (LFPS) and the single-use bougie for tracheal intubation during simulated grade IIIa laryngoscopy. Success rates for intratracheal placement of the device, and the time required for insertion and tracheal intubation were recorded. Both devices were equally successful (31/34 for the LFPS vs 29/34 for the bougie) for insertion into the glottis. The mean insertion time for the LFPS was statistically longer than that for the bougie (4.4-12.5 s) but this difference was not clinically relevant. Intubation times were similar between the two devices. Major problems hindering successful intubation using the LFPS were the presence of a narrow epiglottic-pharyngeal wall space and copious secretions. An inability to maintain the desired shape was the principal cause of failure with the bougie.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bougies as an aid for endotracheal intubation with the Airway Scope: bench and manikin comparison studies

BACKGROUND When encountering a difficult airway with an Airway Scope (AWS) a bougie can be inserted into the endotracheal tube in the AWS channel. The angulated tip of the bougie can be guided toward the glottis by rotating it. We tested the ease of rotating bougies (Venn reusable, Boussignac, Portex single-use, and Frova) in an endotracheal tube when placed in the AWS channel. METHODS Bench ...

متن کامل

Airway scope and gum elastic bougie with Macintosh laryngoscope for tracheal intubation in patients with simulated restricted neck mobility.

BACKGROUND /st> Airway Scope is a new videolaryngoscope which requires less cervical movement during intubation than direct laryngoscopy. Thus, in patients wearing a rigid cervical collar, we compared the efficacy of the Airway Scope and the gum elastic bougie with Macintosh laryngoscope during tracheal intubation. METHODS /st> Anaesthesia was induced with propofol, fentanyl, and rocuronium. ...

متن کامل

A Comparison of Performance of Endotracheal Intubation Using the Levitan FPS Optical Stylet or Lary-Flex Videolaryngoscope in Morbidly Obese Patients

INTRODUCTION The use of videolaryngoscopes is recommended for morbidly obese patients. The aim of the study was to evaluate the Levitan FPS optical stylet (Levitan) vs Lafy-Flex videolaryngoscope (Lary-Flex) in a group of MO patients. METHODS Seventy-nine MO (BMI > 40 kg m(-2)) patients scheduled for bariatric surgery were included in the study and randomly allocated to the Levitan FPS or Lar...

متن کامل

Fibre-optic aided bougie (FAB) for simulated difficult tracheal intubation.

INTRODUCTION Difficult intubation remains a key problem and the value of the gum elastic bougie as a first approach is well recognised. MATERIALS AND METHODS A fine fibre-optic endoscope (Rapiscope, Cook Critical Care) was used in 50 patients to verify placement of a custom-designed hollow plastic bougie prior to "rail-roading" a tracheal tube. Following induction and muscle relaxation, direc...

متن کامل

تاثیر میزان حرکت رو به جلوی فک تحتانی در پیش بینی لوله‌گذاری مشکل داخل تراشه: یک مطالعه آینده‌نگر

Background: Failed endotracheal intubation is one of the principal causes of morbidity and mortality in anesthetized patients. If the anesthetist can anticipate which patients may be more difficult to intubate, can reduce the risks of anesthesia greatly and be more prepared for any difficulties that may occur. The aim of this study was to investigate the inability of patients to protrude the lo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Anaesthesia

دوره 62 5  شماره 

صفحات  -

تاریخ انتشار 2007