Specimen quality is vital to (scanning) transmission electron microscopy (TEM) investigations. In particular, thin specimens are required to obtain excellent high-resolution TEM images. Conventional focused ion beam (FIB) preparation methods cannot be employed to reliably create high quality specimens much thinner than 20 nm. We have developed a method for in situ target preparation of ultrathin TEM lamellae by FIB milling. With this method we are able to routinely obtain large area lamellae with coplanar faces, thinner than 10 nm. The resulting specimens are suitable for low kV TEM as well as scanning TEM. We have demonstrated atomic resolution by Cs-corrected high-resolution TEM at 20 kV on a FIB milled Si specimen only 4 nm thick; its amorphous layer measuring less than 1 nm in total.
منابع مشابه
Sample preparation by focused ion beam micromachining for transmission electron microscopy imaging in front-view.
This article deals with the development of an original sample preparation method for transmission electron microscopy (TEM) using focused ion beam (FIB) micromachining. The described method rests on the use of a removable protective shield to prevent the damaging of the sample surface during the FIB lamellae micromachining. It enables the production of thin TEM specimens that are suitable for p...
متن کاملTEM specimen preparation techniques
Transmission electron microscopy (TEM) is a powerful tool for the investigation of the microstructure of materials, providing crystallographic information and composition at the nanometer scale. For such studies, samples should be transparent to the electron beam. In this review, TEM sample preparation techniques for different classes of materials, such as metals and alloys, multilayered coatin...
متن کاملNovel Hybrid Sample Preparation Method for In Situ Liquid Cell TEM Analysis
In situ environmental transmission electron microscopy (TEM) research has increased dramatically in recent years [1-3]. However, due to the difficulty in sample preparation, liquid environmental TEM studies have been limited to materials such as nanoparticles or nanowires [3-5]. To date, no work has been reported on conventional metals/alloys in liquid environment. This is due to the significan...
متن کاملA novel cryo-FIB lift-out procedure for cryo-TEM sample preparation
The focused-ion-beam (FIB) is the method of choice for site-specific sample preparation for Transmission Electron Microscopy (TEM) in material sciences. A lamella can be physically lifted out from a specific region of a bulk specimen with submicrometer precision and thinned to electron transparency for high-resolution imaging in the TEM. The possibility to use this tool in life sciences applica...
متن کاملUltrathin specimen preparation by a low-energy Ar-ion milling method.
The low-energy Ar-ion milling method was used to prepare ultrathin specimens for transmission electron microscope observation. The samples were thinned initially by a usual focused ion beam technique or typical Ar-ion milling with a high energy of 2-10 keV and were thinned additionally by an Ar-ion beam with an energy less than 1 keV, typically 500-900 eV. This low-energy ion beam was scanned o...