Ophthalmoscopic attachment for the diagnosis of eccentric fixation.

نویسنده

  • H H MASSIE
چکیده

THERE iS much need for earlier and more careful examination of patients, particularly children, who present with amblyopia in a squinting eye, with a view to the detection of eccentric fixation. It is true that in many cases considerable improvement of visual acuity may occur as a result of occlusion of the non-squinting eye, but there are others, mainly those with eccentric fixation, in which vision remains unaffected. Indeed, occlusion of the non-squinting eye only serves to condition the eccentric fixation reflex, when this is present, as well as to increase the macular suppression. Thus treatment of the amblyopia, when it is eventually undertaken on modern lines (Mayweg and Massie, 1958), becomes a more lengthy and uneconomical procedure. Only gross degrees of eccentric ixation can be detected by means of the cover test. Lesser degrees of eccentric fixation, especially when the fixation is perior para-macular, cannot be diagnosed without some special instrument such as the Visuscope, although eccentricity may be strongly suspected to be present in cases in which vision has not improved beyond 6/60, or even 6/24, after several months of total occlusion. The ready availability of a simple instrument for the examination of fixation in these cases of amblyopia is desirable. It is more satisfactory for all concerned if the ophthalmologist can decide about the position of the fixation for himself before treatment is started. For this purpose a palegreen filter (No. 21 pea-green), in which there is a central uncoloured hole of 3/1,000 in., may easily be fitted to most of the ophthalmoscopes in common use. This pale-green filter with the clear centre does not present too great a contrast when viewing the fundus, such as occurs when the green in the filter is too dark. On the Keeler ophthalmoscope this filter can now be supplied as an extra attachment, and it is fitted onto the rotating dome holding the different-sized apertures. A filter can easily be fitted on the A.I.M. ophthalmoscope, and it fits as a cap over the condensing lens on the Lister Morton ophthalmoscope. The white circle of light is clearly projected onto the fundus, and because of the simultaneous contrast, is easily visible

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Changes of Leg Musclus Activities Following Increase of Gait Velocity

Purpose: Motor control evaluation and analysis of it"s specifications for diagnosis of neuromuscular diseases is new approach in clinical electroneurophysiology, that is based on the changes of electromyography responses and classic reflexes in this field. In this study quantitative power spectrum frequency used for changes of motor control strategies. Materials and Methods: Twenty five health...

متن کامل

Trial with red filter in the treatment of eccentric fixation.

FOLLOWING the preliminary reports of Brinker and Katz (1963) and Binder, Engel, Ede, and Loon (1963) on the possible use of a red filter in the management of eccentric fixation, we tried this method of treatment in a series of eighteen cases, ten of which completed the investigation. Six of these were cases of eccentric fixation of the paramacular type, two of the parafoveal type, and two were ...

متن کامل

Comparison of eccentric fixation measurements using the streak target of an ophthalmoscope and a traditional visuoscopy target.

PURPOSE To compare measurements of eccentric fixation using two different targets for fixation, a traditional visuoscope target and the streak target of an ophthalmoscope. PATIENTS AND METHODS Monocular fixation was evaluated using visuoscopy in 47 patients ranging in age from 4 months to 22 years. Visuoscopy measurements were compared using both the traditional visuoscope target and the stre...

متن کامل

On the relationship between strabismic amblyopia and eccentric fixation.

Landolt C and grating acuity are compared with that normally expected of the eccentric fixation region for 10 strabismic amblyopes. The findings suggest that 2 populations of amblyopes exist. For some amblyopes visual function is that predicted of the eccentric region used for fixation, whereas for other amblyopes there is a further pathological reduction in visual function. These findings may ...

متن کامل

Effect of eccentric and inconsistent fixation on retinal optical coherence tomography measures.

OBJECTIVE To assess the relative stabilities of optical coherence tomography (OCT)-based retinal volume and central foveal thickness measurements in the setting of eccentric or inconsistent fixation. METHODS Ten healthy right eyes underwent multiple macular OCT centered at fixation. To model the effect of eccentric or inconsistent fixation, OCT was repeated with scan centers precisely shifted...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 44  شماره 

صفحات  -

تاریخ انتشار 1960