Lung deposition of fenoterol and flunisolide delivered using a novel device for inhaled medicines: comparison of RESPIMAT with conventional metered-dose inhalers with and without spacer devices.
نویسندگان
چکیده
STUDY OBJECTIVES To compare lung deposition of fenoterol or flunisolide administered from a novel, multidose inhalation device delivering liquid droplets (RESPIMAT; Boehringer Ingelheim Ltd; Bracknell, UK) or from conventional metered-dose inhalers (MDIs) with and without spacers. DESIGN Two randomized, three-way crossover studies. SETTING Clinical research laboratory. PARTICIPANTS Healthy, nonsmoking volunteers. INTERVENTIONS In one study, radiolabeled aerosols of fenoterol from the RESPIMAT device and from a conventional MDI with or without an Aerochamber spacer (Trudell Medical; London, Ontario Canada). In the second study, radiolabeled aerosols of flunisolide from a RESPIMAT device, from a RESPIMAT device modified by inclusion of a baffle/impactor in the mouthpiece, and from a conventional MDI with an Inhacort spacer (Boehringer Ingelheim; Ingelheim, Germany). MEASUREMENTS AND RESULTS Assessment of the deposition of fenoterol or flunisolide in the lung and oropharynx using gamma scintigraphy. Safety was assessed based on reported adverse effects and spirometry (FEV1, FVC, and peak expiratory flow rate) to detect any paradoxical bronchoconstriction. The RESPIMAT device delivered significantly more fenoterol to the lungs than either an MDI alone or an MDI with Aerochamber (39.2% vs 11.0% and 9.9% of metered dose, respectively; p<0.01). Oropharyngeal deposition of fenoterol from the new device was lower than that from the MDI (37.1% vs 71.7%, respectively; p<0.01). The RESPIMAT device deposited significantly more flunisolide in the lungs compared with MDI plus spacer (44.6% vs 26.4%, respectively; p<0.01), while resulting in similar oropharyngeal deposition (26.2% vs 31.2%, respectively). Introduction of a baffle into the RESPIMAT system reduced lung deposition of flunisolide to 29.5%, and oropharyngeal deposition to 7.8% (p<0.01). CONCLUSION The RESPIMAT device may prove to be an effective alternative to MDIs for the administration of inhaled bronchodilators and corticosteroids. The high lung deposition and low oropharyngeal deposition may lead to improved efficacy and tolerability of inhaled medications, especially corticosteroids.
منابع مشابه
Use of Respimat® Soft Mist™ Inhaler in COPD patients
Events of the past decade have stimulated development of new drug formulations and delivery devices that have improved the efficiency, ease of use, and environmental impact of inhaled drug therapy. Respimat Soft Mist Inhaler is a novel, multidose, propellant-free, hand-held, liquid inhaler that represents a new category of inhaler devices. The aerosol cloud generated by Respimat contains a high...
متن کاملHigher lung deposition with Respimat® Soft Mist™ Inhaler than HFA-MDI in COPD patients with poor technique
Aerosols delivered by Respimat Soft Mist Inhaler (SMI) are slower-moving and longer-lasting than those from pressurized metered-dose inhalers (pMDIs), improving the efficiency of pulmonary drug delivery to patients. In this four-way cross-over study, adults with chronic obstructive pulmonary disease (COPD) and with poor pMDI technique received radiolabelled Berodual (fenoterol hydrobromide 50 m...
متن کاملInhaled corticosteroid delivery systems: clinical role of a breath-actuated device.
Several devices have been developed to overcome the need to co-ordinate actuation with inhalation required during use of a pressurised metered dose inhaler (MDI) and to improve drug delivery to the lung. These include spacer attachments for MDIs, dry powder inhalers and breath-actuated MDIs. The breath-actuated Autohaler (3M Pharmaceuticals) is a compact, multidose inhaler device that, unlike d...
متن کاملPatient preferences for inhaler devices in chronic obstructive pulmonary disease: experience with Respimat® Soft Mist™ Inhaler
Current guidelines for the management of chronic obstructive pulmonary disease (COPD) recommend the regular use of inhaled bronchodilator therapy in order to relieve symptoms and prevent exacerbations. A variety of inhaler devices are currently available to COPD patients, and the choice of device is an important consideration because it can influence patients' adherence to treatment, and thus p...
متن کاملSystematic review of clinical effectiveness of pressurised metered dose inhalers versus other hand held inhaler devices for delivering corticosteroids in asthma.
OBJECTIVE To determine the clinical effectiveness of pressurised metered dose inhalers (with or without spacer) compared with other hand held inhaler devices for the delivery of corticosteroids in stable asthma. DESIGN Systematic review of randomised controlled trials. DATA SOURCES Cochrane Airways Group trials database (Medline, Embase, Cochrane controlled clinical trials register, and han...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Chest
دوره 113 4 شماره
صفحات -
تاریخ انتشار 1998