Onboard determination of submicromolar nitrate in seawater by anion-exchange chromatography with lithium chloride eluent.

نویسندگان

  • Masahiro Maruo
  • Takashi Doi
  • Hajime Obata
چکیده

Ion-exchange chromatography using a high-capacity anion exchanger with UV detection was applied to the determination of nitrate in seawater. Major ions in seawater samples did not affect the peak shape and the retention time of the nitrate when an alkaline metal cation-chloride solution was used as an eluent at high concentrations (0.5-2 mol/l). At a wavelength of 220 nm, the peak of bromide was very small because of low absorption, while its separation from the nitrate peak was good at high concentrations. Among the eluents tested, lithium chloride gave the best separation of nitrate from bromide. It was estimated that the lithium ion had the least potential for ion-pair formation with nitrate, and its retention time was prolonged compared with the retention times when using other cations; with bromide and nitrite, such an effect was not observed. The results of shipboard seawater nitrate determination by our method in the South Pacific Ocean and Antarctic Sea showed good agreement with those by the conventional photometric method using continuous flow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of trace anions in high-nitrate matrices by ion chromatography.

An ion chromatography method was developed to determine trace anionic contamination in matrices that have a high concentration of nitrate ion. Contaminant anions of interest were separated on an IonPac AS15 high-capacity anion-exchange column and detected by suppressed conductivity detection. An EG40 eluent generator was used to prepare high-purity and carbonate-free potassium hydroxide. Using ...

متن کامل

Determination of anions at trace levels in power plant water samples by ion chromatography with electrolytic eluent generation and suppression.

An ion chromatographic method was developed for the determination of nine inorganic and organic acid anions at sub- to low-microg/l levels in power plant water samples. In this method, samples were injected using a large-volume direct injection technique, the analyte anions were separated on a hydroxide-selective anion-exchange column using high-purity hydroxide eluents generated by an on-line ...

متن کامل

Ion chromatography for determination of nitrite and nitrate in seawater using monolithic ODS columns.

A fast and highly sensitive ion chromatographic method using monolithic ODS columns was developed for the determination of nitrite (NO2-) and nitrate (NO3-) in seawater. Two monolithic ODS columns (50 mm x 4.6 mm i.d. + 100 mm x 4.6 mm i.d.) connected in series were coated and equilibrated with 5 mM cetyltrimethylammonium chloride (CTAC) aqueous solution. The column efficiency with 0.5 M NaCl a...

متن کامل

The Preconcentration and Determination of Pb2+, Cu2+, Co2+, Ni2+, Fe2+ and Zn2+ Elements in Water Samples Using Citrate Form of Anion-Exchange Resin

Lead, copper, cobalt, nickel, iron and zinc ions form monocitrate complexes (negative charge) in citrate solution which is absorbed on the citrate form of anion-exchange resins (citrate as counter ion) y exchange of citrate ion with citrate complexes. These are subsequently recovered from the resin by 0.5M ammonium citrate eluent at pH 2.0. Under optimized conditions, quantitative recovery ...

متن کامل

Simplified column-switching technology for the determination of traces of anions in the presence of high concentrations of other anions.

A binary eluent model was proposed to study the retention behavior of trace anions in the presence of high concentrations of co-eluent anions. According to this model, the effect of the matrix on the retention of trace anions can be suppressed by using a high-concentration eluent. Based on the model, a simplified 'heart-cut' column-switching technology was proposed, in which the column-switchin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 22 9  شماره 

صفحات  -

تاریخ انتشار 2006