Prosthetic arteriovenous grafts for hemodialysis.
نویسنده
چکیده
INTRODUCTION Prosthetic arteriovenous (AV) grafts are indicated in patients with failed AV fistula (AVF), exhausted superficial veins or unsuitable vessels. Increasing the proportion of prevalent hemodialysis (HD) patients using autogenous AVF should reduce the need for AV grafts and associated morbidity. This paper reviews the current role of prosthetic AV grafts in vascular access for HD. TECHNICAL CONSIDERATIONS Prior to the insertion of a prosthetic AV graft, a comprehensive review of previous access procedures and full physical examination in addition to vessel mapping is required. Anastomotic technique should take into account the flow diffuser concept, graft geometry and an anastomotic angle of 15 degrees in order to reduce the incidence of intimal hyperplasia. RESULTS Many authors report 1 and 2-yr cumulative graft patency rates of 59-90% and 50-82%, respectively. The major drawbacks with synthetic grafts include: thrombosis, a five-fold increase in infection risk and steal syndrome. The choice between surgical and percutaneous methods of dealing with blocked AV grafts remains controversial, though percutaneous techniques are assuming an increasingly important role. Percutaneous strategies are successful in declotting access in 67-95% of cases. Stenting of stenotic lesions following thrombectomy improves secondary patency rates. Strategies for dealing with AV graft infection include antibiotic prophylaxis, partial, subtotal or total graft excision and the use of biological prosthesis. CONCLUSIONS Though more prone to complications than autogenous AVFs, AV grafts offer a short maturation period and are more amenable to thrombectomy by radiological or surgical means. Complex AV grafts may be appropriate in patients with exhausted access sites.
منابع مشابه
Prosthetic Arteriovenous Graft Contact Dermatitis Masquerading as an Arteriovenous Graft Infection in a Hemodialysis Patient
Prosthetic arteriovenous (AV) graft is the second most common vascular access of choice in hemodialysis patients. Rare complications of such grafts are increasingly seen due to rising population of patients on hemodialysis. Infections and thrombosis are the most common complications. Though metallic implants are known to cause hypersensitivity skin reactions, prosthetic AV grafts are rarely kno...
متن کاملبررسی میزان کارایی و عوارض گرافت صناعی عروقی پلی تترا فلورو اتیلن در بیماران همودیالیزی
Background: Dialysis access procedures and complications are important causes of morbidity and hospitalization for chronic hemodialysis patients. Ideally, any patient undergoing hemodialysis should receive an autogenous fistula that can be accessed throughout the patient's life. In patients with primarily unsuitable or secondarily surgically-exhausted veins, a prosthetic graft can be performed....
متن کاملClinical Analysis of Hemodialysis Vascular Access: Comparision of Autogenous Arterioveonus Fistula & Arteriovenous Prosthetic Graft
BACKGROUND Mature autogenous arteriovenous fistulas have better long term patency and require fewer secondary interventions compared to arteriovenous prosthetic graft. Our Study evaluated vascular patency rates and incidence of interventions in autogenous arteriovenous fistulas and grafts. MATERIAL AND METHODS A total of 166 vascular access operations were performed in 153 patients between De...
متن کاملThe Brachio-Brachial Arteriovenous Fistula
The autogenous arteriovenous fistula (AVF) is the preferred access for chronic hemodialysis in patients with end-stage kidney disease. Careful examination of the upper extremity is essential for the creation of a successful fistula. The quality of the arterial and venous circulation should be well established prior to surgery. However, there are cases when the superficial venous system of the u...
متن کاملDistal emboli as an unusual late complication of a thrombosed arteriovenous hemodialysis graft.
The creation of an arteriovenous fistula for long-term hemodialysis access is one of the most commonly performed procedures in vascular and transplantation surgery. Prosthetic conduits are frequently prone to failure within their first year of construction, and after one or two revisions, they are left in their thrombosed state as permanent subcutaneous foreign bodies in the extremities. Conven...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The journal of vascular access
دوره 10 3 شماره
صفحات -
تاریخ انتشار 2009