Statistical properties of pulsatile pressure and flow in the femoral artery of the dog.

نویسنده

  • J E RANDALL
چکیده

Femoral pulsatile pressure and flow in anesthetized dogs were measured as time series. The computed cross products of pressure and flow were also expressed as time series. The statistical variance (<J-) of each of these was analyzed into a frequency spectrum. The spectral magnitudes at each frequency were used to compute the pressure-flow coherence, impedance magnitude and phase angle as a function of frequency. The high coherency between pressure and flow at most frequencies indicated that a linear deterministic model may suffice to express the opposition to flow pulsations. The impedance variation with frequency indicated that the model may be frequency dependent. Computed autocorrelation and cross correlation functions measured the statistical nature of the observed time series.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Case Report of Ruptured Superficial Femoral Artery Aneurysm

Single superficial femoral artery (SFA) aneurysm is rare and occurs in approximately 5 per 100,000 patients. Rupture is a rare complication in this aneurysm. In this case report, we present the diagnostic and therapeutic work up of a ruptured SFA aneurysm of the right lower limb in a 75-year-old diabetic man with ischemic heart disease. Pre-surgical diagnosis was through physical examination fi...

متن کامل

Effect of six non-Newtonian viscosity models on hemodynamic parameters of pulsatile blood flow in stenosed artery

A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with non-Newtonian models using ADINA. Blood flow was considered laminar, and the arterial wall was considered rigid. Studied stenosis severities were 30, 50, and 70% of the cross-section...

متن کامل

An implicit finite difference scheme for analyzing the effect of body acceleration on pulsatile blood flow through a stenosed artery

With an aim to investigate the effect of externally imposed body acceleration on two dimensional,pulsatile blood flow through a stenosed artery is under consideration in this article. The blood flow has been assumed to be non-linear, incompressible and fully developed. The artery is assumed to be an elastic cylindrical tube and the geometry of the stenosis considered as time dependent, and a co...

متن کامل

Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall

Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been  introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the  substitution  of  the  blood  pressure  changes  in  the  central  arteries  such  as  carotid  with  the  blood  pressure  changes in the brachial results in error in the blood...

متن کامل

Evaluating the effect of stenosis increase and pulsatile blood pressure on effective stress distribution in viscoelastic finite element model based on carotid artery ultrasound images

The aim of this study is to evaluate the changes of effective stress distribution in plaque by progressing to the stenosis throat and to assess the pulsatile pulse pressure effect on effective stress of a viscoelastic finite-element model of carotid arteries having less and more than 50% stenosis. In-vivo geometries of the arteries were reconstructed using consecutive transverse ultrasound imag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation research

دوره 6 6  شماره 

صفحات  -

تاریخ انتشار 1958