A comparison between low-dose and standard-dose non-contrasted multidetector CT scanning of the paranasal sinuses

نویسندگان

  • SY Lam
  • SI Bux
  • G Kumar
  • KH Ng
  • AF Hussain
چکیده

PURPOSE To compare the image quality of the low-dose to the standard-dose protocol of MDCT scanning of the paranasal sinuses, based on subjective assessment and determine the radiation doses to the eyes and thyroid gland and dose reduction between these two protocols. MATERIALS AND METHODS 31 adult patients were scanned. Prior to scanning, thermoluminescent dosimeters (TLDs) were placed at 4 sites: outer canthus of right eye, outer canthus of left eye, inner canthus and anterior neck (thyroid gland). Every patient was scanned twice using the standard-dose protocol (100mAs) followed by the low-dose protocol (40mAs). The images were reviewed by 3 radiologists. Wilcoxon test was used as the test of significance for the image quality assessments. The paired sample t-test was used as the test of significance for the analysis of the radiation doses measured by the TLDs. RESULTS Of the 30 patients selected for analysis, this study showed no significant difference in the scores for the diagnostic image quality and the anatomical structures assessments between the two protocols. The average calculated mean entrance surface doses and standard deviation for the standard-dose and low-dose protocols were 12.40±1.39 mGy and 5.53±0.82 mGy respectively to the lens and 1.03±0.55 mGy and 0.63±0.53 mGy respectively to the thyroid gland. CONCLUSION The reduction of mAs from 100 to 40 resulted in a significant reduction of the radiation doses to the lens and thyroid gland by 55.4% and 38.8% respectively without causing any significant effect to the diagnostic image quality and assessment of the anatomical structures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Image Optimization and reduction of radiation dose in CT of the paranasal sinuses

Introduction: Since demand for computed tomography (CT) examinations is growing, patients are exposed more frequently to ionizing radiation. To reduce the dose delivered to patients in each scan, CT technologists can change the image acquisition parameters. However, this reduces image quality. Present study aimed to optimize and reduce radiation dose in a CT of the paranasal si...

متن کامل

Comparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism

Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...

متن کامل

بررسی دقت تشخیصی Limited Screening CT و مقایسه با CT استاندارد در تشخیص سینوزیت

Background and purpose : Çoronal ÇT scan of paranasal sinuses with contiguous images is the gold standard technique in diagnosis of sinusitis. Çonsidering the expense and high dose of radiation in conventional ÇT scan, clinical measurements and simple radiography is not enough sensitive and specific, some workers have suggested limited screening (non contiguous) instead of conventional ÇT ima...

متن کامل

Comparison of simulated cone beam computed tomography to conventional helical computed tomography for imaging of rhinosinusitis.

OBJECTIVES/HYPOTHESIS Cone beam computed tomography (CBCT) has emerged as a low radiation dose alternative to traditional computed tomography (CT) to evaluate the paranasal sinuses. The purpose of our study was to determine how often clinically important findings would be missed if CBCT was used routinely for sinus imaging. STUDY DESIGN Retrospective review. METHODS We evaluated all maxillo...

متن کامل

Sinonasal Anatomical Variations: A Multidetector Computed Tomographic Study

Background and Aim: The paranasal sinuses are known for their complex anatomy and significant difference in size and shape. This study aimed to determine the prevalence of anatomical variations of the paranasal sinuses in computed tomography (CT). Materials and Methods: In this cross-sectional study, patients over 18 years of age, who had undergone CT imaging in a private clinic, were screened...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2009