Temperature-controlled cooled-tip radiofrequency linear ablation of the atria guided by a realtime position management system.

نویسندگان

  • Ichiro Watanabe
  • Nuo Min
  • Yasuo Okumura
  • Kimie Ohkubo
  • Masayoshi Kofune
  • Sonoko Ashino
  • Koichi Nagashima
  • Toshiko Nakai
  • Yuji Kasamaki
  • Atsushi Hirayama
چکیده

Due to the difficulty in producing a transmural linear lesion and the possibility of complications such as thrombus formation leading to thromboembolism, the catheter-based maze procedure remains problematic. We tested, in pigs, the possibility of using a temperature-controlled cooled-tip radiofrequency (RF) ablation system together with a realtime position management (RPM) system to create a transmural linear lesion uncomplicated by thrombus formation.Nine pigs underwent insertion of two electrode catheters (each with two ultrasound electrodes), one into the coronary sinus (CS) and one into the right ventricular apex (references for ultrasound-based non-fluoroscopic three-dimensional mapping). A cooled-tip catheter (with two ultrasound electrodes) was introduced into the right atrium. Linear right atrial ablation was performed with a custom radiofrequency (RF) generator. The catheter was perfused with 0.66 mL/second of saline. RF was delivered for 60 seconds at a target temperature of 40°C. A linear ablation line was created between the superior vena cava and inferior vena cava. Three-dimensional isochronal maps were created during CS pacing before and after ablation. In 4 of the 9 pigs, a transmural linear ablation line was confirmed by three-dimensional mapping and postmortem macroscopic examination. No endocardial thrombus formation was noted. Temperature-controlled cooled-tip RF linear ablation guided by an RPM system appears to have potential for creating linear lesions in the atria. Further studies are needed to determine whether such an ablation technique and the parameters used will facilitate successful completion of the catheter-based maze procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relative brightness due to temperature changes with ultrasound image analysis during Radiofrequency ablation

Introduction: Diagnosis of primary and secondary cancers to treat patients with diffuse and malignant tumors is an important subject. The appropriate treatment will be eliminating primary and metastatic tumors. Radiofrequency ablation with localized heat induction in the target tissue causes irreversible cellular damage and tissue coagulation. Estimation of tissue temperature c...

متن کامل

Convective cooling effect on cooled-tip catheter compared to large-tip catheter radiofrequency ablation.

BACKGROUND Both actively cooled-tip and large-tip catheters are currently available clinically to create large endomyocardial lesions during application of radiofrequency (RF) energy. The purpose of this study was to compare the effect of convective cooling at physiologic flow rates on RF lesion size using both actively cooled and large-tip catheters. METHODS Porcine hearts were sectioned int...

متن کامل

Are the Virtual Lines Created with the Ensite Electroanatomical Mapping System Really Continuous?

BACKGROUND EnSiteNavx electroanatomic mapping system is widely used in radiofrequency (RF) atrial fibrillation ablation, helping the creation of linear lesions. However, the correspondence of the virtual line created by EnSite with the pathological lesion has not yet been evaluated. OBJECTIVE to assess the continuousness of Ensite-guided virtual lines in a swine model. METHODS we performed ...

متن کامل

Discrepancies between catheter tip and tissue temperature in cooled-tip ablation: relevance to guiding left atrial ablation.

BACKGROUND It is not known whether catheter tip temperatures with a cooled-tip ablation can be reliably extrapolated to estimate actual tissue temperatures. The relationship between catheter tip temperatures, tissue temperatures, power, and microbubble formation is not known. METHODS AND RESULTS Nine dogs underwent 111 radiofrequency energy deliveries at the pulmonary vein ostia with a cooled...

متن کامل

Features : Cooled Tip Catheter Ablation

Just over a decade ago, the advent of tip temperature monitoring during radiofrequency (RF) energy delivery marked the beginning of a second generation of ablation catheter technology and furthered the success of catheter ablation as a therapeutic tool. RF generators were designed with a closed-loop feedback system to automatically adjust power output to avoid temperatures that would cause coag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International heart journal

دوره 52 1  شماره 

صفحات  -

تاریخ انتشار 2011