The feasibility and radiological features of sacral alar iliac fixation in an adult population: a 3D imaging study

نویسندگان

  • Ai-Min Wu
  • Yong-Long Chi
  • Wen-Fei Ni
  • Yi-Xing Huang
  • Ferdinand Frauscher
چکیده

BACKGROUND Surgical treatments for adult spinal deformities often include pelvic fixation, and the feasibility of sacral-2 alar iliac (S2AI) screw fixation has been shown previously. However, sometimes S2AI screw fixation cannot be applied due to the presence of an osteolytic lesion or trauma or because the biomechanical properties of only an S2AI screw is insufficient. Therefore, we questioned the feasibility of using sacral AI screws in other segments and determined whether S3AI and S4AI screws have the potential to be used for sacral fractures. The aim of this study was to investigate the feasibility and radiological features of sacral AI fixation in S1-S4 in an adult population using 3D imaging techniques. METHODS Computed tomography (CT) scans were taken of 45 patients and were imported into Mimics (Version 10.01, Materialise, Belgium) software to reconstruct the 3D digital images. Next, a cylinder (radius of 3.5 mm) was drawn to imitate the screw trajectory of a S1-4 AI screw, and every imitated screw in each segment was adjusted to a maximum upward and downward angle to acquire the feasible region. The parameters of the S1-4AI screw trajectories were measured. RESULTS Sacral AI screws could be successfully imitated using 3D digital imaging. The S4AI screw trajectory could be obtained in 19 of 45 patient images (42.2%), while the feasibility rates of S1AI, S2AI, and S3AI screw fixation were 100%, 100%, and 91.1% (41/45), respectively. The feasible regions of S1AI, S2AI, and S3AI screw trajectories were wide enough, while the adjustable angle of S4AI screws was very small. CONCLUSION It is feasible to place S1-2AI screws in the entire adult population and S3-4AI screws in some of the adult population. Furthermore, our study suggested that 3D digital images are suitable to study the feasibility of new screw fixation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous S2 alar iliac fixation for pelvic insufficiency fracture.

Pelvic insufficiency fractures are fairly common in elderly patients and can be a source of major functional impairment, particularly when they involve the ilium. Early rehabilitation with adequate pain relief has been the traditional method of treatment. The recently developed S2 alar iliac technique involves placing pelvic fixation into the ilium through a pathway from the sacral ala. The bon...

متن کامل

Proper detailed parameters for S1 sacral alar iliac screw placement in the Chinese population, a 3D imaging study.

BACKGROUND S1-AI technique may be used as a salvage technique in pelvic fixation of complex spinal deformity surgery. However, the proper detailed parameters in the Chinese population has not been analyzed before to instruct S1-AI screws placement and to ensure the safety of clinical application while the trajectory in pelvic changes significantly at each angle. RESULTS The ideal S1AI screw t...

متن کامل

Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System

  Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...

متن کامل

Fabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System

Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...

متن کامل

Use of S2-Alar-iliac Screws Associated With Less Complications Than Iliac Screws in Adult Lumbosacropelvic Fixation.

STUDY DESIGN Retrospective comparative study. OBJECTIVE To compare clinical and radiographic outcomes between the S2-alar-iliac (S2AI) and the iliac screw (IS) techniques in the adult population and clarify the clinical strength of S2AI screws. SUMMARY OF BACKGROUND DATA S2AI screws have been described as an alternative method for lumbosacropelvic fixation in place of ISs. The S2AI techniqu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016