A practical method to determine the healing and cooling curves of x-ray tube assemblies.

نویسندگان

  • M Bottaro
  • M Moralles
  • V Viana
  • G L Donatiello
  • E P Silva
چکیده

A practical method to determine the heating and cooling curves of x-ray tube assemblies with rotating anode x-ray tube is proposed. Available procedures to obtain these curves as described in the literature are performed during operation of the equipment, and the precision of the method depends on the knowledge of the total energy applied in the system. In the present work we describe procedures which use a calorimetric system and do not require the operation of the x-ray equipment. The method was applied successfully to a x-ray tube assembly that was under test in our laboratory.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

متن کامل

Producion of Nanoparticle Assemblies by Electro-Spraying and Freeze-Drying of Colloids: A New Method to Resolve Handling Problem of Nanoparticles

To resolve handling problem of nanoparticles, due to their small size, a new methodology of electro-spraying and freeze-drying was developed for colloidal nanoparticles of silica and titania to transform them to solid macro-scale nanoparticle assemblies.  The assemblies were then redispersed in an aqueous system to investigate the effect of formulation of original solutions and the process ...

متن کامل

Quality assessment of conventional X-ray diagnostic equipment by measuring X-ray exposure and tube output parameters in Great Khorasan Province, Iran

Introduction: Regular implementation of quality control (QC) program in diagnostic X-ray facilities may affect both image quality and patient radiation dose due to the changes in exposure parameters. Therefore, this study aimed to investigate the status of randomly selected conventional radiographic X-ray devices installed in radiology centers of Great Khorasan Province, Iran, to produce the da...

متن کامل

Performance Evaluation of Diagnostic X-Ray Equipment Regarding the Hospital Size in the Republic of Korea

  Introduction: The Republic of Korea has developed a national standard based on which diagnostic X-ray equipment must be tested every 3 years. Accordingly, the performance of X-ray equipment used in all hospitals is evaluated by national certification bodies in compliance with the safety management regulations for X-ray equipment. However, if the equipment i...

متن کامل

بهینه‌سازی بازتابش آینه‌های نانو - چند لایه‌ای متناوب پرتو ایکس در سه انرژی لبه جذبTi-Kα و Co-Kα و Cr-Kα

In this paper, a practical simulation method for optimizing of x-ray reflection of nano-multilayer mirrors in three different edge energies: Cr-Kα, Co-Kα, and Ti-Kα is discussed in order to obtain the most reflection based on quarter-wave thickness method (QW). In this method, the reflected x-ray will have a constructive interference, and a peak, called Brag peak, will appear in reflection curv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 34 10  شماره 

صفحات  -

تاریخ انتشار 2007