Light microscopy and scanning electron microscopy analysis of rigid curved interface femtosecond laser-assisted and manual anterior capsulotomy.
نویسندگان
چکیده
PURPOSE To study the microanatomic edge structures of anterior lens capsule specimens derived from manual and femtosecond laser-assisted capsulotomies. SETTING Department of Ophthalmology, Goethe-University, Frankfurt, Germany. DESIGN Experimental study. METHODS Of 60 eyes with lens removal and intraocular lens implantation, 30 received a manual capsulotomy and 30 received a femtosecond laser-assisted capsulotomy (Lensx, rigid curved interface, pulse energy 15 μJ, spot separation 4 μm, layer separation 3 μm). After anterior capsule removal, tissues were immediately fixed in 4.5% formalin. Approximately 30 minutes after fixation, the tissues were removed from the fixation containers and air dried for at least 2 hours. Fifteen capsules in each group had further staining for light microscopy (LM). The surface of the capsulotomy edge was the primary focus of LM and scanning electron microscopy (SEM). Cell configuration, capsule shape, and abnormalities were evaluated. RESULTS Subjective LM and SEM analysis showed smooth edges at all magnifications, no cell destruction, and cells up to the cutting edge in the manual capsulotomy group. Light microscopy demonstrated almost continuous anterior capsule incisions of the femtosecond laser-assisted capsulotomy, a prominent demarcation line along the cutting edge, and several tags and bridges. Scanning electron microscopy showed microgrooves and valley- and mountain-like structures as signs of the photodisruption process. CONCLUSION Compared with manual procedures, curved, rigid interface femtosecond laser-assisted capsulotomy specimens using 15 μJ pulse energy showed tags, bridges, rougher edges, and demarcation lines on the capsulotomy edges on SEM but subjectively estimated a more round shape on LM. FINANCIAL DISCLOSURES Mr. Klaproth received travel reimbursements and/or lecture fees from Alcon Laboratories, Inc., Rayner Intraocular Lenses Ltd., and Oculus GmbH. Dr. Kohnen received travel reimbursements, grant support, and/or lecture fees from Alcon Laboratories, Inc., Abbott Medical Optics, Inc., Bausch & Lomb, Carl Zeiss Meditec AG, Neoptics AG, Rayner Intraocular Lenses Ltd., and Schwind eye-tech-solutions GmbH and Co. KG; he is a consultant to Alcon Laboratories, Inc., Carl Zeiss Meditec AG, Rayner Intraocular Lenses Ltd., and Schwind eye-tech-solutions GmbH and Co. KG. No other author has a financial or proprietary interest in any material or method mentioned.
منابع مشابه
Analysis of Femtosecond Laser Assisted Capsulotomy Cutting Edges and Manual Capsulorhexis Using Environmental Scanning Electron Microscopy
Purpose. To investigate the structure and irregularity of the capsulotomy cutting edges created by two femtosecond (FS) laser platforms in comparison with manual continuous circular capsulorhexis (CCC) using environmental scanning electron microscopy (eSEM). Methods. Ten anterior capsulotomies were obtained using two different FS laser cataract platforms (LenSx, n = 5, and Victus, n = 5). In ad...
متن کاملInitial clinical evaluation of an intraocular femtosecond laser in cataract surgery.
PURPOSE To evaluate femtosecond laser lens fragmentation and anterior capsulotomy in cataract surgery. METHODS Anterior capsulotomy and phacofragmentation procedures performed with an intraocular femtosecond laser (LenSx Lasers Inc) were initially evaluated in ex vivo porcine eyes. These procedures were then performed in an initial series of nine patients undergoing cataract surgery. In addit...
متن کاملIdeal parameters for femto-second laser-assisted anterior capsulotomy: Animal studies
In femtosecond laser-assisted cataract surgery, the parameter such as horizontal spot spacing and energy level can be adjusted. Although there have been several studies reported on various laser systems, showing the effects of varying energy levels and horizontal spot spacing on lens capsulotomy cut edges, none have been reported on the Catalys laser system (Abbott Medical Optics, Inc., Santa A...
متن کاملPerforming Reliable Lens Capsulotomy in the Presence of Corneal Edema With a Femtosecond Laser.
Purpose To determine the effects of the Ziemer LDV Z8 liquid interface femtosecond laser platform during capsulotomy under different energy settings in the presence of corneal edema. Methods Cadaveric porcine eyes (n = 36) employed at less than 6 and greater than 24 post enucleation hours to simulate clear/edematous corneas, underwent capsulotomy with the Ziemer LDV Z8 femtosecond laser (5-mm...
متن کاملComparative Study of Corneal Endothelial Cell Damage after Femtosecond Laser Assisted Deep Stromal Dissection
PURPOSE To find a relatively safe designed stromal bed thickness to avoid endothelial damage for lamellar keratoplasty with an Allegretto Wavelight FS200 femtosecond laser. METHODS Twelve rabbits were randomly divided into 50 μm and 150 μm groups according to the anticipated residue stromal bed thickness preparation with a femtosecond laser. Six rabbits without laser cutting were used as a co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 39 10 شماره
صفحات -
تاریخ انتشار 2013