Outcomes of instrumented fusion in the pediatric cervical spine.
نویسندگان
چکیده
OBJECT The most common cause of cervical spine arthrodesis in the pediatric population is instability related to congenital or traumatic pathology. Instrumenting the cervical spine can be challenging given smaller anatomical structures, less ossified bone, and future growth potential and development. Studies in adult patients have suggested that using screw constructs results in improved outcomes with lower rates of instrumentation failure. However, the pediatric literature is limited to small retrospective series. Based on a review of the literature and their own patient series, the authors report that instrumenting the pediatric cervical spine with screw constructs may be safer and more effective than using wiring techniques. METHODS The authors reviewed the existing pediatric cervical spine arthrodesis literature and contributed 31 of their own cases from September 1, 2007, to January 1, 2011. They reviewed 204 abstracts from January 1, 1966, to December 31, 2010, and 80 manuscripts with 883 total patients were included in the review. They recorded demographic, radiographic, and outcomes data-as well as surgical details-with a focus on fusion rates and complications. Patients were then grouped into categories based upon the procedure performed: 1) patients who underwent fusions bridging the occipitocervical junction and 2) patients who underwent fusion of the cervical spine that did not include the occiput, thus including atlantoaxial and subaxial fusions. Patients were further subdivided according to the type of instrumentation used-some had posterior cervical fusion with wiring (with or without rod implantation); others had posterior cervical fusion with screws. RESULTS The entire series comprised 914 patients with a mean age of 8.30 years. Congenital abnormalities were encountered most often (in 55% of cases), and patients had a mean follow-up of 32.5 months. From the entire cohort, 242 patients (26%) experienced postsurgical complications, and 50 patients (5%) had multiple complications. The overall fusion rate was 94.4%. For occipitocervical fusions (N = 285), both screw and wiring groups had very high fusion rates (99% and 95%, respectively, p = 0.08). However, wiring was associated with a higher complication rate. From a sample of 252 patients, 14% of those treated with screw instrumentation had complications, compared with 50% of patients treated with wiring (p < 0.05). In cervical fusions not involving the occipitocervical junction (N = 181), screw constructs had a 99% fusion rate, whereas wire instrumentation only had an 83% fusion rate (p < 0.05). Similarly, patients who underwent screw fixation had a lower complication profile (15%) when compared with those treated with wiring constructs (54%, p < 0.05). CONCLUSIONS The results of this study are limited by variations in construct design, use of orthoses, follow-up duration, and newer adjuvant products promoting fusions. However, a literature review and the authors' own series of pediatric cases suggest that instrumentation of the cervical spine in children may be safer and more efficacious using screw constructs rather than wiring techniques.
منابع مشابه
The Use of Bone Morphogenetic Protein in Pediatric Cervical Spine Fusion Surgery: Case Reports and Review of the Literature
Study Design Case report. Objective There is a paucity of literature describing the use of bone graft substitutes to achieve fusion in the pediatric cervical spine. The outcomes and complications involving the off-label use of bone morphogenetic protein (BMP)-2 in the pediatric cervical spine are not clearly defined. The purpose of this article is to report successful fusion without complicatio...
متن کاملInstrumented cervical spinal fusions in children: indications and outcomes
Purpose To report indications, outcomes and complications of instrumented cervical spinal fusion in a consecutive series of children at major university hospitals. Methods A retrospective, single surgeon series identified 35 consecutive children with a mean follow-up (FU) of 2.5 years undergoing instrumented cervical spinal fusion between 2005 and 2015. Results The main indications were ske...
متن کاملLaminoplasty instead of laminectomy as a decompression method in posterior instrumented fusion for degenerative cervical kyphosis with stenosis
BACKGROUND Posterior laminectomy with instrumented fusion is a standard procedure for treating degenerative cervical kyphosis with stenosis (DCKS). Two major disadvantages of the surgery are adhesion of the dural membrane with significant disfiguring of cervical spine and a small fusion bed around the lateral mass. One of the advantages of laminoplasty over laminectomy is the protection of the ...
متن کاملMinimally invasive cervical spine foraminotomy and lateral mass screw placement.
STUDY DESIGN This technique article describes accomplishing multilevel posterior cervical decompression and lateral mass screw placement through a tubular retraction system. OBJECTIVE Multilevel foraminotomy and instrumented fusion using lateral mass screw fixation can be achieved through a minimally invasive technique using specialized retractors and intraoperative fluoroscopic imaging. SU...
متن کاملComparison of outcomes and safety of using hydroxyapatite granules as a substitute for autograft in cervical cages for anterior cervical discectomy and interbody fusion
Background: After cervical discectomy, autogenetic bone is packed into the cage to increase the rate of union between adjacent vertebral bodies, but donor site–related complications can still occur. In this study we evaluate the use of hydroxyapatite granules as a substitute for autograft for interbody fusion. Methods: From November 2008 to November 2011, 236 patients participated in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of neurosurgery. Spine
دوره 17 5 شماره
صفحات -
تاریخ انتشار 2012