Spiral MRI on rat brain and rat heart at 7 Tesla
نویسندگان
چکیده
INTRODUCTION: Although quite similar in many aspects, the spiral imaging technique features several advantages over Echo Planar Imaging (EPI). Especially, (i) higher acquisition speed, due to a more efficient use of the gradient hardware (the two in-plane channels operate simultaneously, applying waveforms optimized to fully exploit the amplifiers), (ii) very short minimum echo time (TE), with a trajectory starting from the k-space centre and (iii) good flow properties, due to gradient moment nulling. Two experiments performed at 7 T on rats are presented here. They take advantage of these remarkable features and demonstrate the feasibility of spiral MR imaging for small animal studies at high B0 fields. PURPOSE: The purpose of this study is to show the potential of the spiral k-space scanning method for functional MRI and cardiovascular animal applications at high field. An image comparison is performed in order to assess the image quality obtained with spiral and with EPI acquisitions, both very prone to B0 in-homogeneity artifacts. METHODS: A spiral imaging method has been implemented in the ParaVision® environment (Bruker BioSpin MRI GmbH, Ettlingen, Germany). It allows the two-dimensional trajectory to be measured and processed [1]. The spiralacquired data are reconstructed with a conventional regridding algorithm using a Kaiser-Bessel function as convolution kernel [2]. The MRI experiments were performed on a 7 T, 16 cm diameter bore, PharmaScan® (Bruker BioSpin MRI GmbH, Ettlingen, Germany) equipped with a B-GA9S gradient coil (Gmax = 366 mT/m, slew rate max = 3424 T/m/sec). Birdcage resonators of 38 mm and 60 mm diameters were used respectively for the brain and for the heart experiments. Rats were anesthetized with isoflurane at 1-2.5 %. For brain experiments, first and second order shims were adjusted with FASTMAP over a voxel of (7.8mm)3 positioned at the front lobe of the rat brain, where the five imaged slices were located. For more flexibility, all single and multi-shot trajectories were calibrated directly on the animal. A spatial resolution of 469 μm was chosen, corresponding to a 3 cm FOV and a matrix size of 64x64. With acquisition bandwidths of 450 kHz and 250 kHz respectively, the spiral acquisition duration was 12.1 ms while the EPI one was 17.2 ms. For the selected FOV (3 cm) the upper limit of the EPI bandwidth was 250 kHz because of gradient hardware constraint applies on the EPI readout channel, while a 450 kHz bandwidth was possible for the spiral protocol. The images were acquired using the shortest TE achievable for the desired spatial resolution (EPI) and slice thickness (spiral, EPI). Minimum TEs of 1.1 ms and 6.7 ms were found for gradient echo (GE) spiral and EPI techniques, respectively. Performing the same experiments with a spin echo (SE) preparation scheme leads to TEs of 5.4 ms and 16.3 ms, respectively. For heart experiments, a global first order shim was performed. The heart slice of interest was first localized with a T2* weighted sequence (FLASH, TR/TE: 52/2 ms). Because of the beating motions preventing proper in vivo trajectory measurement, the trajectories were measured on a completely homogeneous phantom (water solution with CuSO4 1 g/l) prior to acquire in vivo images. A sixteen-shot spiral scan was used for cardiac acquisitions with a TR/TE of 10/1.6 ms allowing 15 frames to be measured for covering the whole cardiac cycle (350 bpm). Each shot was synchronized with the rat ECG and breathing signals. All movie frames were acquired for each shot. Eight scans were averaged, resulting in a total scan time of 19.2 seconds for the whole cardiac cycle. The chosen spatial resolution was 625 μm corresponding to a FOV of 6 cm and a matrix size of 96x96. RESULTS: A comparison is shown between single-shot GE (B) and SE (C) rat brain spiral images and single-shot GE (D) and SE (E) EPI images. All brain experiments were performed with saturation slices in order to suppress the brain surrounding tissues located outside the FOV. Because of shorter TE and shorter gradient application duration, spiral images suffer from fewer B0 in-homogeneity artefacts and thus provide a better level of details than EPI images. On image (A), one spiral heart image taken from a cardio cycle movie acquired in 19.2 seconds is shown. CONCLUSIONS: Constant improvements in MRI hardware allow on one side to shorten the spiral readout gradient duration gradient amplifiers and actively shielded coils, increased sampling rates (digital receiver allowing acquisition bandwidths up to 1 MHz) and on another side to decrease the residual B0 in-homogeneities gradientintegrated shim coils allowing very good shim performances. Both factors concur to make possible new in vivo applications of spiral MRI on small animals and at high B0 fields. As shown by our preliminary results at 7 T, spiral MRI can be a good alternative to EPI especially for fMRI, perfusion, cardiovascular or diffusion applications. To our knowledge this is the first described study demonstrating the spiral technique for rat imaging with good spatial resolution at high field. REFERENCES: [1] Y. Zhang et al. Magn Reson Med. 1998; 39: 999-1004. [2] J.I. Jackson et al. IEEE Trans. Med. Im. 1991, 10: 473-478. B A C
منابع مشابه
Magnetic Graphene Oxide Nanocarrier as a drug delivery vehicle for MRI monitored magnetic targeting of rat brain tumors
Introduction: Glioblastoma multiform is the most common malignant brain tumor, with an invasive nature. Despite the development of conventional therapies such as surgery, radiotherapy and chemotherapy, because of high recurrence rates, the prognosis remains very poor. Over the last decade, nanotechnology has represented an innovative method as nanoparticle-based drug delivery ...
متن کامل11.7T MR Imaging Revealed Dilatation of Virchow–Robin Spaces within Hippocampus in Maternally Lipopolysaccharide-exposed Rats
PURPOSE 11.7 Tesla MRI was examined to detect Virchow-Robin spaces (VRSs) smaller than 100 μm in the rat brain. The effects of maternal exposure to lipopolysaccharide (LPS) were evaluated on basis of the number of dilated VRSs in the offspring rat brain. METHODS T2-weighted MRI with an in-plane resolution up to 78 μm (repetition time = 5000 ms, echo time = 35 ms, slice thickness = 250 μm, ima...
متن کاملApparent Diffusion Coefficient Mapping Using a Multi-Shot Spiral MRI Sequence of the Rat Brain
Purpose: Commonly used diffusion weighted (DW) imaging such as DW spin echo (SE) type echo planar imaging (DW-SE-EPI) is known to be a snapshot-like acquisition and to have a relatively high signal-to-noise ratio. Spiral MRI sequence (SPIRAL) has characteristics similar to these of EPI, but it has rarely been used for diffusion-weighted imaging (DWI). In vivo DW-SPIRAL of the rat brain has almo...
متن کاملRelaxation time constants and apparent diffusion coefficients of rat retina at 7 Tesla
MRI has recently been applied to study the retina in vivo. Measurements of relaxation time constants (T1, T2, and T2*) and the apparent diffusion coefficient (ADC) of the retina would be useful to systemically optimize structural, physiological, and functional MRI contrasts. MRI studies were performed on 12 anesthetized and paralyzed rats. High-resolution T1, T2, T2* and ADC of the rat eyes wer...
متن کاملTraumatic Brain Injury Has Not Prominent Effects on Cardiopulmonary Indices of Rat after 24 Hours: Hemodynamic, Histopathology, and Biochemical Evidence
Background: Accidents are the second reason for mortality and morbidity in Iran. Among them, brain injuries are the most important damage. Clarification of the effects of brain injuries on different body systems will help physicians to prioritize their treatment strategies. In this study, the effect of pure brain trauma on the cardiovascular system and lungs 24 hours post trauma was assessed. M...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005