High mass accuracy and high mass resolving power FT-ICR secondary ion mass spectrometry for biological tissue imaging.

نویسندگان

  • Donald F Smith
  • Andras Kiss
  • Franklin E Leach
  • Errol W Robinson
  • Ljiljana Paša-Tolić
  • Ron M A Heeren
چکیده

Biological tissue imaging by secondary ion mass spectrometry has seen rapid development with the commercial availability of polyatomic primary ion sources. Endogenous lipids and other small bio-molecules can now be routinely mapped on the sub-micrometer scale. Such experiments are typically performed on time-of-flight mass spectrometers for high sensitivity and high repetition rate imaging. However, such mass analyzers lack the mass resolving power to ensure separation of isobaric ions and the mass accuracy for elemental formula assignment based on exact mass measurement. We have recently reported a secondary ion mass spectrometer with the combination of a C60 primary ion gun with a Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) for high mass resolving power, high mass measurement accuracy, and tandem mass spectrometry capabilities. In this work, high specificity and high sensitivity secondary ion FT-ICR MS was applied to chemical imaging of biological tissue. An entire rat brain tissue was measured with 150 μm spatial resolution (75 μm primary ion spot size) with mass resolving power (m/Δm(50%)) of 67,500 (at m/z 750) and root-mean-square measurement accuracy less than two parts-per-million for intact phospholipids, small molecules and fragments. For the first time, ultra-high mass resolving power SIMS has been demonstrated, with m/Δm(50%) > 3,000,000. Higher spatial resolution capabilities of the platform were tested at a spatial resolution of 20 μm. The results represent order of magnitude improvements in mass resolving power and mass measurement accuracy for SIMS imaging and the promise of the platform for ultra-high mass resolving power and high spatial resolution imaging.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spatial segmentation of MALDI FT-ICR MSI data: a powerful tool to explore the head and neck tumor in situ lipidome.

Matrix-assisted laser desorption/ionization mass spectrometric imaging (MALDI MSI) is a well-established analytical technique for determining spatial localization of lipids in biological samples. The use of Fourier-transform ion cyclotron resonance (FT-ICR) mass spectrometers for the molecular imaging of endogenous compounds is gaining popularity, since the high mass accuracy and high mass reso...

متن کامل

Petroleomics: advanced molecular probe for petroleum heavy ends.

To look into complex mixtures of petroleum heavy ends at the molecular level, ultra high-resolution mass spectrometry, i.e. resolving power > 50,000, is needed to resolve overlapping components for accurate determination of molecular composition of individual components. Recent progress in Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) incorporated with soft ionization ...

متن کامل

An improved calibration method for the matrix-assisted laser desorption/ionization-Fourier transform ion cyclotron resononance analysis of 15N-metabolically- labeled proteome digests using a mass difference approach.

High mass measurement accuracy of peptides in enzymatic digests is critical for confident protein identification and characterization in proteomics research. Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) can provide low or sub-ppm mass accuracy and ultrahigh resolving power. While for ESI-FT-ICR-MS, the mass accuracy is generally 1 ppm or better, with matrix-assisted l...

متن کامل

Fourier Transform Ion Cyclotron Resonance mass spectrometry for plant metabolite profiling and metabolite identification.

Mass spectrometry (MS) is usually the technique of choice for metabolomic studies where the volume of sample material is too limited for applications employing nuclear magnetic resonance (NMR) spectroscopy. With the advent of ultra-high accuracy mass spectrometers such as the Orbitrap (resolution ∼ 10(5)) and the Fourier Transform Ion Cyclotron Resonance (FT-ICR) analysers (resolution potential...

متن کامل

Fourier transform ion cyclotron resonance mass spectrometry: a primer.

This review offers an introduction to the principles and generic applications of FT-ICR mass spectrometry, directed to readers with no prior experience with the technique. We are able to explain the fundamental FT-ICR phenomena from a simplified theoretical treatment of ion behavior in idealized magnetic and electric fields. The effects of trapping voltage, trap size and shape, and other nonide...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical and bioanalytical chemistry

دوره 405 18  شماره 

صفحات  -

تاریخ انتشار 2013