Monitor unit optimization in RapidArc plans for prostate cancer
نویسندگان
چکیده
Intensity-modulated radiation therapy (IMRT) has become a standard treatment for prostate cancer based on the superior sparing of the bladder, rectum, and other surrounding normal tissues compared to three-dimensional conformal radiotherapy, despite the longer delivery time and the increased number of monitor units (MU). The novel RapidArc technique represents a further step forward because of the lower number of MUs per fraction and the shorter delivery time, compared to IMRT. This paper refers to MU optimization in RA plans for prostate cancer, using a tool incorporated in Varian TPS Eclipse. The goal was to get the lowest MU RA plan for each patient, keeping a well-defined level of PTV coverage and OAR sparing. Seven prostate RA plans (RA MU-Optimized) were retrospectively generated using the MU optimization tool in Varian Eclipse TPS. Dosimetric outcome and nontarget tissue sparing were, compared to those of RA clinical plans (RA Clinical) used to treat patients. Compared to RA Clinical, RA MU-Optimized plans resulted in an about 28% (p = 0.018) reduction in MU. The total integral dose (ID) to each nontarget tissue (but not the penile bulb) showed a consistent average relative reduction, statistically significant only for the femoral heads. Within the intermediate dose region (40-60 Gy), ID reductions (4%-17% p < 0.05) were found for the rectum, while a slight but significant (0.4%-0.9%, p < 0.05) higher ID was found for the whole body. Among the remaining data, the mean dose to the bladder was also reduced (-12%, p = 0.028). Plans using MU optimization are clinically applicable and more MU efficient, ameliorating the exposure of the rectum and the bladder to intermediate doses.
منابع مشابه
Feasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment
The volumetric modulated arc therapy (VMAT) technique, in the form of RapidArc, is widely used to treat prostate cancer. The full-single arc (f-SA) technique in RapidArc planning for prostate cancer treatment provides efficient treatment, but it also delivers a higher radiation dose to the rectum. This study aimed to compare the dosimetric results from the new partial-single arc (p-SA) techniqu...
متن کاملDosimetric Comparison and Evaluation of 4 Stereotactic Body Radiotherapy Techniques for the Treatment of Prostate Cancer
PURPOSE The aim of this study was to compare dosimetric characteristics, monitor unit, and delivery efficiency of 4 different stereotactic body radiotherapy techniques for the treatment of prostate cancer. METHODS This study included 8 patients with localized prostate cancer. Dosimetric assets of 4 delivery techniques for stereotactic body radiotherapy were evaluated: robotic CyberKnife, nonc...
متن کاملComparison of dose distribution in IMRT and RapidArc technique in prostate radiotherapy.
AIM The aim was to provide a dosimetric comparison between IMRT and RapidArc treatment plans with RPI index with simultaneous comparison of the treatment delivery time. BACKGROUND IMRT and RapidArc provide highly conformal dose distribution with good sparing of normal tissues. However, a complex spatial dosimetry of IMRT and RapidArc plans hampers the evaluation and comparison between plans c...
متن کاملUnderstanding the impact of RapidArc therapy delivery errors for prostate cancer
The purpose of this study is to simulate random and systematic RapidArc delivery errors for external beam prostate radiotherapy plans in order to determine the dose sensitivity for each error type. Ten prostate plans were created with a single 360° arc. The DICOM files for these treatment plans were then imported into an in-house computer program that introduced delivery errors. Random and syst...
متن کاملA RapidArc planning strategy for prostate with simultaneous integrated boost
Since the clinical implementation of novel rotational forms of intensity-modulated radiotherapy, a variety of planning studies have been published that reinforce the major selling points of the technique. Namely, comparable or even improved dose distributions with a reduction in both monitor units and treatment times, when compared with static gantry intensity-modulated radiotherapy. Although t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 14 شماره
صفحات -