Alps Locking Plate System – Introduction & Application

نویسنده

  • Geoffrey Hutchinson
چکیده

The ALPS (Advanced Locking Plate System) fracture fixation system is a novel internal fracture fixation device designed and produced by Kyon Veterinary Surgical Products of Switzerland. Compared to conventional internal fixation systems the ALPS system is designed to reduce the rate of surgical infection, improve the rate of fracture healing, and improve surgical application versatility. All ALPS implants are titanium or titanium alloy. Compared to surgical stainless steel, titanium has greater biocompatibility, reduced infection rates, and a favorable tradeoff between ductility and strength. The geometry of ALPS plates is computer-optimized to reduce regions of stress-concentration and to facilitate bending/contouring both out-of-plane and in-plane. Screw holes accommodate either conventional bone screws or locking screws. Conventional bone screws may be placed with up to 60 degrees of longitudinal and 10 degrees of transverse swivel and can be used to apply dynamic compression across the fracture or to lag fragments through the plate. Locking screws are placed perpendicular to the plate and compared to conventional screws provide improved construct rigidity even when placed monocortically. ALPS plates are applied in direct contact with the bone. The bone-plate contact region is a small “point” contact that assures stability of the construct while minimizing the area of compressive damage to periosteal blood vessels. When used with locking screws, monocortical screw placement minimizes damage to the endosteal blood vessels and the trans bone cortex. The reduced iatrogenic impact to periosteal and endosteal bone vascular supply has been shown to reduce infection rate and bone healing time. Compared to internal locking systems and external fixators that are applied at a distance away from the bone, contact of the ALPS plate with the bone reduces interference with overlying soft tissues and, as it is nearer to the axial center of the bone, reduces transferred forces on the plate, screws, and screw-bone interface. A minimum of three points of bone contact for each placed screw ensures construct rigidity. The point contact design and application of the plate in dynamic compression mode require contouring of the ALPS plate to match the geometry of the bone. The specific bending pliers and bending irons facilitate in-plane and out-of-plane bending of the plate to conform to bone contours. Specific drill guides are provided for placement of locking screws and for placement of conventional screws in neutral and dynamic compression modes. The point-contact internal fixator design concept of ALPS was initially developed and tested as PC-fix. Although never commercially released, this system was demonstrated experimentally and clinically to have improved rates of infection compared to conventional internal fixation compression plates. A point-contact internal fixator implant design (PC-fix) was shown to have a significantly reduced rate of infection when compared experimentally to a conventional dynamic compression plate in a bacteria-contaminated rabbit experimental model. In 1172 clinical applications of PC-fix, the reported rate of infection was 1.1% overall, 1.6% in open fractures, and 1.0% in closed fractures. The ALPS system has been available for veterinary clinical use since 2007 and is used in over 60 clinics worldwide. ALPS is available in 5 different plate sizes using three different sets of screws and instrumentation. This array of implants accommodates patients throughout the range of body sizes presented in small animal practice. ALPS is exceptionally versatile for use in long bone fractures of all sorts. The low profile of the system allows placement into regions of

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single cycle to failure in torsion of three standard and five locking plate constructs.

OBJECTIVES The biomechanical properties of standard plates and recently designed locking plates were compared in torsion. We hypothesized that titanium (Ti) constructs would have the greatest deformation, and String of Pearls (SOP) constructs the greatest strength and stiffness. METHODS Dynamic compression plates (DCP), stainless steel (SS) limited contact (LC)-DCP, Ti LC-DCP, locking compres...

متن کامل

The Outcome of Proximal Humeral Locking Plates in the Management of Three and Four Part Proximal Humeral Fractures in Special Cohort of Young Patients in High Velocity Trauma

Background: Locking plate fixation provides satisfactory outcome following proximal humerus fractures. None of theprevious studies selectively evaluate the outcome in young patients. This study evaluates outcome of locking platesystem in the treatment of acute three- and four-part fractures in young patients.Methods: In this prospective study we included all patients who were less than 60 years...

متن کامل

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...

متن کامل

Increased rates of wound complications with locking plates in distal fibular fractures.

INTRODUCTION There is a growing use of locking compression plates in fracture surgery. The current study was undertaken to investigate the wound complication rates of locking versus non-locking plates in distal fibular fractures. PATIENTS AND METHODS During a 6-year study period all consecutive, closed distal fibular fractures treated with either a locking or a non-locking plate were included...

متن کامل

Supracondylar Osteotomy in Valgus Knee: Angle Blade Plate Versus Locking Compression Plate

  Background: There are few studies comparing the biomechanical properties of angled blade plate and locking compression plates in supracondylar osteotomy. In the current randomized study, we prospectively compared the clinical and radiological outcomes of supracondylar osteotomy using these two plates. Methods: Forty patients with valgus knee malalignment were randomly assigned to two equal nu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012