Can Achilles tendon be used as a new distal landmark for coronal tibial component alignment in total knee replacement surgery? An observational MRI study

نویسندگان

  • Uğur Tiftikçi
  • Sancar Serbest
  • Veysel Burulday
چکیده

BACKGROUND In total knee arthroplasty, it is better to use more than one reference point for correct alignment of the components. By measuring the distances of Achilles tendon (AT) and other conventional landmarks from the mechanical axis in magnetic resonance imaging (MRI) of the ankle, we aimed to demonstrate that, as a novel landmark which can help for correct alignment in the coronal plane, AT is a better option than other landmarks. MATERIALS AND METHODS This retrospective study was done on 53 ankle MRIs that met the criteria for inclusion to the study among 158 ankle MRIs. After identification of the mechanical axis, the distances of distal landmarks, which were extensor hallucis longus tendon (EHLT), tibialis anterior tendon (TAT), dorsalis pedis artery (DPA), AT, extensor digitorum longus tendon (EDLT), and malleoli, were measured from the mechanical axis and were statistically evaluated. RESULTS In proximal measurements, the distances of the landmarks to the mechanical axis (on average) were AT, 2.64±1.62 mm lateral; EHLT, 3.89±2.45 mm medial; DPA, 4.69±2.39 mm medial; TAT, 8.24±3.60 mm medial; and EDLT, 14.2±4.14 mm lateral (P<0.001). In distal measurements, the distances of the landmarks to the mechanical axis (on average) were AT, 1.99±1.24 mm medial; EHLT, 4.27±2.49 mm medial; DPA, 4.79±2.10 mm medial; TAT, 12.9±4.07 mm medial; and EDLT, 12.18±4.17 mm lateral (P<0.001). CONCLUSION In this study, the mechanical axis line, which is the center of talus, passes through the AT. Our MRI investigations showed that the AT, EHLT, DPA, and malleolar center (3-5 mm medial) may help in correct alignment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving tibial component coronal alignment using clearly defined anatomical structures in total knee arthroplasty.

Several authors recently proposed to use clearly defined anatomical structures for extramedullary tibial alignment in total knee replacement, instead of using the intermalleolar center. The purpose of this study was to evaluate the benefits of using the dorsalis pedis artery and the anterior tibial crest as distal landmarks. Postoperative radiographs in 195 knees (98 in the control and 97 in th...

متن کامل

Extramedullary versus intramedullary tibial cutting guides in megaprosthetic total knee replacement

BACKGROUND In a standard total knee replacement, tibial component alignment is a key factor for the long term success of the surgery. The purpose of this study is to compare the accuracy of extramedullary and intramedullary tibial cutting guides used in indigenous and imported implants respectively, in positioning of the tibial components in megaprosthetic knee replacements. METHODS A compara...

متن کامل

A Comparison of Bony Landmarks in the Distal Femur and the Tibial Shaft: Whichlandmark Should Be Used in Total Knee Arthroplasty?

INTRODUCTION: Correct rotational alignment of the femoral component is one of the most important factors for successful total knee arthroplasty. The rotational position of the femoral component can be determined using bony landmarks, such as the transepicondylar axis, the posterior condylar axis, or the anteroposterior (AP) axis (Whiteside’s line). Rotational alignment of the femoral component ...

متن کامل

Early Results of Oxford Mobile Bearing Medial Unicompartmental Knee Replacement (UKR) with the Microplasty Instrumentation: An Indian Experience

Background: Oxford medial unicompartmental knee replacement (UKR) is indicated in patients with anteromedialosteoarthritis (AMOA) of the knee. Microplasty (MP) instrumentation was introduced in 2012 as an improvement overphase 3 instrumentation. Advantages of this instrumentation include conservative tibial cut, decreased tibial re-cut rateand improved component alignment. We report the results...

متن کامل

Distal femoral condyle is more internally rotated to the patellar tendon at 90° of flexion in normal knees

BACKGROUND The configuration of the distal surface of the femur would be more important in terms of the patellofemoral (PF) joint contact because the patella generally contacts with the distal surface of the femur in knee flexion. Some total knee arthroplasty (TKA) designs configurate medially prominent asymmetric femoral condyles. This difference in the design of distal femoral condyle may aff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2017